REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 49-91-52-000-001 Removal of the Generator Scavenge Pump (8085KM) (GTCP 36-300)
AMM 49-91-52-400-001 Installation of the Generator Scavenge Pump (8085KM) (GTCP 36-300)
AMM 49-94-13-000-001 Removal of the High Oil-Temperature Switch (8090KM) (GTCP 36-300)
AMM 49-94-13-400-001 Installation of the High Oil-Temperature Switch (8090KM) (GTCP 36-300)
3. Fault Confirmation__________________
A. Do the subsequent checks and the operational test of the APU.
(1) Do a check and make sure that the cooling fan inlet duct, the oil cooler inlet duct and the oil cooler outlet duct are correctly attached and in the correct condition.
- correct/replace as necessary.
(2) Do a check with your hand for soft areas and damage for components which follow:
- cooling fan inlet-duct (collapsed);
- cooling fan outlet-duct;
- oil cooler inlet-duct.
NOTE : Replace damaged component as necessary.
____
(a) If a hand check does not confirm the fault but a damaged duct is still suspected:
- do a start (Ref. AMM TASK 49-00-00-860-003) of the APU to look for duct collapse.
(3) Do a check and make sure that the LUBE-PUMP OIL FILTER and the GENERATOR OIL FILTER indicators are not protruded (Ref. AMM TASK 49-91-00-210-001).
(4) Do the operational test of the APU (Ref. AMM TASK 49-00-00-710-004).
NOTE : Operate the APU for min. 15 minutes under full load. This
____ makes sure that the oil temperature increases sufficiently.
4. Fault Isolation
_______________
**ON A/C 001-003, 051-062,
A. If an APU auto shutdown occurs during the operational test of the APU and the APU SHUTDOWNS report gives the maintenance message:
HIGH OIL TEMPERATURE - OIL COOLER OR COOLING FAN OR GEN SCAVENGE PUMP:
- replace the OIL TEMPERATURE SWITCH P11 (Ref. AMM TASK 49-94-13-000-001) and (Ref. AMM TASK 49-94-13-400-001).
(1) If the fault continues:
- replace the OIL COOLER (Ref. AMM TASK 49-91-44-000-001)and (Ref. AMM TASK 49-91-44-400-001).
(2) If the fault continues:
- replace the COOLING FAN (Ref. AMM TASK 49-52-51-000-001) and (Ref. AMM TASK 49-52-51-400-001).
(3) If the fault continues:
- replace the GENERATOR SCAVENGE PUMP (Ref. AMM TASK 49-91-52-000-001) and (Ref. AMM TASK 49-91-52-400-001).
(4) If the fault continues:
- replace the APU GENERATOR(8XS) (Ref. AMM TASK 24-23-51-000-001) and (Ref. AMM TASK 24-23-51-400-001).
(5) If the fault continues:
- replace the ECB (59KD) (Ref. AMM TASK 49-61-34-000-001) and (Ref. AMM TASK 49-61-34-400-001).
(6) If the fault continues:
- replace the AUXILIARY POWER UNIT (4005KM) (Ref. AMM TASK 49-11-11-000-001) and (Ref. AMM TASK 49-11-11-400-001).