 4. Fault Isolation
_______________
 A. If the APU Last Leg Report gives the maintenance message:
 LOW OIL LEVEL:
 Fault Code Number: 048

 - do a visual check on the oil sight glass on the accessory drive gearbox and make sure that the oil level in the APU oil reservoir is sufficient.
 (1) If the oil level is not sufficient:
 - do the oil servicing (Ref. AMM TASK 49-90-00-600-004).

 - calculate the APU oil consumption.


 (a) If there is a sudden increase in the APU oil consumption:
 - carefully examine the APU externally and make sure that you do not find leaks on the oil system components or oil lines.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 106-106, 108-149, 211-299, 301-399, ∞∞49-00-00∞∞∞∞∞∞∞∞∞∞Page 280
 Config-2 Aug 01/05 CES 1 If you find external oil leaks:

 

_

 - correct/replace as necessary.
 2 If you do not find external oil leaks:

_ - examine the APU for internal oil leaks. a If the fault continues:

_

 - replace the AUXILIARY POWER UNIT (4005KM) (Ref. AMM TASK 49-11-11-000-003) and (Ref. AMM TASK 49-11-11-400-003).
 (b) If the oil level is sufficient:
 - do a check and repair the wiring from the ECB (59KD) AB/H2, J4 to the OIL LEVEL SENSOR (8089KM) P8/1, 2, (Ref. ASM 49-61/02).
 1 If the fault continues:
_

 - replace the ECB (59KD) (Ref. AMM TASK 49-61-34-000-002) and (Ref. AMM TASK 49-61-34-400-002)

 B. Do the test given in para. 3.

 

 TASK 49-00-00-810-921
 Fumes in the Cabin/Oil Smoke at the APU Exhaust (APS 3200)
 1. Possible Causes
_______________
 - plumbing

 - PMG and COOLING FAN ASSEMBLY (8055KM)

 - OIL COOLER
 - oil pump assembly
 - oil filler cap and scupper


 - pressure fill and overflow ports

 - GEN-APU 8XS

 - Oil Pressure Switch

 - AUXILIARY POWER UNIT (4005KM)

 - AUXILIARY POWER UNIT 4005KM

 - unwanted material in the internal areas of the air inlet duct, the air intake diffuser and elbow

 - flexible seals on the air intake system

 - alignment of the air inlet duct


 2. Job Set-up Information
______________________
 A. Consumable Materials
 -------------------------------------------------------------------------------
REFERENCE  DESIGNATION
 -------------------------------------------------------------------------------
No specific  overflow drain tool
 B. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE  DESIGNATION
 -------------------------------------------------------------------------------
AMM 12-33-21-618-001 Pre-conditioning with the APU AMM 21-00-00-615-001 Decontamination of the Environmental Control System (ECS) when the Temperature is below 24 deg.C (APU) AMM 21-00-00-615-002 Decontamination of the Environmental Control System (ECS) when the Temperature is above 24 deg.C (APU)
 AMM 21-00-00-615-003  Decontamination of the Environmental Control System (ECS) when the Temperature is below 24 deg.C (Engine/s)
 AMM 21-00-00-615-004  Decontamination of the Environmental Control System (ECS) when the Temperature is above 24 deg.C (Engine/s)
 AMM 24-23-51-000-001 Removal of the APU Generator 8XS AMM 24-23-51-400-001 Installation of the APU Generator 8XS AMM 49-00-00-100-002 Cleaning of the APU Compartment with installed APU AMM 49-11-11-000-003 Removal of the Power Plant (APU) (APS 3200)
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 106-106, 108-149, 211-299, 301-399, ∞∞49-00-00∞∞∞∞∞∞∞∞∞∞Page 282
 Config-2 Aug 01/05 CES -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------

 

AMM 49-11-11-400-003 Installation of the Power Plant (APU) (APS 3200) AMM 49-16-00-100-002 Cleaning of the APU Air Intake System (APS 3200) AMM 49-16-00-210-002 Detailed Inspection of APU Air Intake, Diffuser
 Elbow, Seals and Felt Metal (APS 3200) AMM 49-20-00-290-001 APU Power Plant Borescope Inspection (APS 3200) AMM 49-52-53-000-001 Removal of the PMG and Cooling Fan Assembly (8055KM)
 (APS 3200) AMM 49-52-53-400-001 Installation of the PMG and Cooling Fan Assembly
 (8055KM) (APS 3200) AMM 49-90-00-600-004 Check Oil Level and Replenish (APS 3200) AMM 49-91-44-000-003 Removal of the Oil Cooler (8079KM) (APS 3200) AMM 49-91-44-400-003 Installation of the Oil Cooler (8079KM) (APS 3200) AMM 49-94-14-000-002 Removal of the Oil Pressure Switch (8091KM) (APS
 