R 1EFF : 001-049, 054-099, 101-149, 201-299, 1 27-21-00Page 619 1301-399, 1May 01/05 1 1 1CES 1
R (6) In the zone 161, install the partition panels 161DW, 162DW (Ref. TASK
R 25-55-12-400-001).
R (7) Close the access doors 312AR, 825, 826.
R (8) Remove the access platform(s).
**ON A/C ALL
Subtask 27-21-00-860-057
C. Put the aircraft back to its initial configuration.
(1) Remove the warning notice(s).
(2) De-energize the ground service network (Ref. TASK 24-42-00-862-001).
TASK 27-21-00-220-001 Check of the Tension of the Rudder Mechanical-Control Cables with a Tensiometer WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
_______ GEAR.
WARNING : MAKE SURE THAT THE CONTROLS AGREE WITH THE POSITION OF THE ITEMS THEY
_______ OPERATE BEFORE YOU PRESSURIZE A HYDRAULIC SYSTEM.
WARNING : MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROL SURFACES ARE
_______ CLEAR BEFORE YOU PRESSURIZE/DEPRESSURIZE A HYDRAULIC SYSTEM.
WARNING : PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU
_______ START A TASK ON OR NEAR:
-
THE FLIGHT CONTROLS
-
THE FLIGHT CONTROL SURFACES
-
THE LANDING GEAR AND THE RELATED DOORS
-COMPONENTS THAT MOVE.
1.
Reason for the Job
__________________
Refer to the MPD TASK: 272100-03
2.
Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific tensiometer No specific warning notices No specific access platform 2.06 m (6 ft. 9 in.)
1EFF : ALL 1 27-21-00Page 621 1 1 May 01/05R 1 1 1CES 1
B. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied from the External Power 25-54-12-000-002 Removal of the Ceiling Panels in the FWD Cargo Compartment 25-54-12-400-002 Installation of the Ceiling Panels in the FWD Cargo Compartment 25-55-11-000-002 Removal of the Ceiling Panels in the AFT Cargo Compartment - FR47/FR59 25-55-11-400-002 Installation of the Ceiling Panels in the AFT Cargo Compartment -FR47/FR59
27-21-00-820-002 Adjustment of the Rudder Control-Cables Length
R 27-21-45-000-001 Removal of the Cable Tension Regulator Assy
R 27-21-45-400-001 Installation of the Cable Tension Regulator Assy 29-10-00-863-003 Pressurize the Blue Hydraulic System with a Ground Power Supply 29-10-00-864-003 Depressurize the Blue Hydraulic System 52-30-00-860-001 Open the FWD or AFT Cargo-Compartment Door with the Yellow Electric Pump 52-30-00-860-002 Close the FWD or AFT Cargo-Compartment Door with the Yellow Electric Pump