 (12GV,13GV,14GV,15GV) AMM 32-49-16-400-005 Installation of the MLG Tire-Pressure Transducer
 (12GV,13GV,14GV,15GV) AMM 32-49-17-000-001 Removal of the NLG TPIS Rotating Mechanism AMM 32-49-18-000-001 Removal of the Rotating Mechanism AMM 32-49-18-400-001 Installation of the Rotating Mechanism AMM 32-49-34-000-001 Removal of the TPIS Detection Unit (2GV) AMM 32-49-34-400-001 Installation of the TPIS Detection Unit (2GV)
 3. Fault Confirmation
__________________
 A. Job Set-up
 (1) Aircraft Maintenance Configuration
 (a) Energize the aircraft electrical circuits
 (Ref. AMM TASK 24-41-00-861-002)


 (b) Do the EIS start procedure (Lower ECAM DU only) (Ref. AMM TASK 31-60-00-860-001).

 


 B. Test

 

 (1) On the ECAM control panel:

 - push the WHEEL key to get the WHEEL page.

 (2) Do a check of the disagree between the TPIS value shown on the lower ECAM DU and the pressure gage value on the related tire (TPIS value less than or equal to 95 % pressure gage value) (Ref. AMM TASK 32-41-00-210-003).


 4. Fault Isolation
_______________
 A. If the test confirms the fault:
 - replace the related pressure transducer on the MLG (Ref. AMM TASK 32-49-16-000-005) and (Ref. AMM TASK 32-49-16-400-005) or on the NLG (Ref. AMM TASK 32-49-15-000-001) and (Ref. AMM TASK 32-49-15-400-001).
 (1) If the fault continues:

 - replace the DETECTOR UNIT-TPIS (2GV) (Ref. AMM TASK 32-49-34-000-001) and (Ref. AMM TASK 32-49-34-400-001).

 (2) If the fault continues:


 - replace the related rotating mechanism on the MLG (Ref. AMM TASK 32-49-18-000-001) and (Ref. AMM TASK 32-49-18-400-001) or on the NLG (Ref. AMM TASK 32-49-17-000-001) and (Ref. AMM TASK 32-49-17-000-001).
 B. Do the test given in Para. 3.B.
 5. Close-up
________
 A. Put the aircraft back to its initial configuration.
 (1) On the ECAM control panel, set the LOWER DISPLAY potentiometer to OFF.

 (2) De-energize the aircraft electrical circuits
 (Ref. AMM TASK 24-41-00-862-002).

 

 

 TASK 32-49-00-810-825

 

 TPIS Value Shown on the Lower ECAM DU Less than or Equal to 95 % Pressure Gage Value for two Wheels and more
 1. Possible Causes
_______________
 - DETECTOR UNIT-TPIS (2GV)
 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power AMM 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
 from the External Power AMM 31-60-00-860-001 EIS Start Procedure AMM 32-41-00-210-003 Inspection/Check of the Pressure of Tires AMM 32-49-34-000-001 Removal of the TPIS Detection Unit (2GV) AMM 32-49-34-400-001 Installation of the TPIS Detection Unit (2GV)
 3. Fault Confirmation
__________________
 A. Job Set-up
 (1) Aircraft Maintenance Configuration
 (a) Energize the aircraft electrical circuits
 (Ref. AMM TASK 24-41-00-861-002).


 (b) Do the EIS start procedure (Lower ECAM DU only) (Ref. AMM TASK 31-60-00-860-001).


 B. Test
 (1) On the ECAM control panel:

 - push the WHEEL key to get the WHEEL page.

 (2) Do a check of the disagree between the TPIS values shown on the lower ECAM DU and the pressure gage values on two wheels and more (TPIS value less than or equal to 95 % pressure gage value) (Ref. AMM TASK 32-41-00-210-003).

 


 4. Fault Isolation
_______________


 A. If the test confirms the fault:
 - replace the DETECTOR UNIT-TPIS (2GV) (Ref. AMM TASK 32-49-34-000-001) and (Ref. AMM TASK 32-49-34-400-001).
 B. Do the test given in Para. 3.B.
 5. Close-up
________
 A. Put the aircraft back to its initial configuration.
 (1) On the ECAM control panel, set the LOWER DISPLAY potentiometer to OFF.

 (2) De-energize the aircraft electrical circuits
 (Ref. AMM TASK 24-41-00-862-002).

 

 


 TASK 32-49-00-810-826
 Loss of the BUS2 Output Signal from the TPIU (Identified by the ECAM1 or 2)
 1. Possible Causes
_______________
 - DETECTOR UNIT-TPIS (2GV)

 - wiring from the TPIU (2GV) pins AB/2A, 2B to the first terminal block


 2. Job Set-up Information
______________________
 