R A. If the test confirms the fault:
R (1) Do a check for leakage of the parking brake control valve (102GG): 
R - on the Yellow brake-system relief-valve (3067GM) operate the manual 
R depressurization pushbutton to release the accumulator pressure. on 
R the Yellow hydraulic system, depressurize the hydraulic reservoir 
R (Ref. AMM 29140061400100). 
R - on the accumulator pressure gage (2585GM) make sure that nitrogen 
R pressure is correct (Ref. AMM 32441120000100). 
R - on the parking brake control valve at port C (service supply line), 
R disconnect the hydraulic line. 
R - install a plug at port C of the parking selector valve (102GG) and 
R on the disconnected hydraulic line. 
R - on the parking brake selector valve (102GG) at port B (return 
R line), at the Tlevel, disconnect the hydraulic line between the 
R parking brake control valve (102GG) and the T fitting. 
R - install a plug on the T fitting. 
R - on the Yellow hydraulic sytem, pressurize the hydraulic reservoir 
R (Ref. AMM TASK 29-14-00-614-002). 
R - use the Yellow electric pump to pressurize the Yellow brake 
R accumulator (2582GM) to 206 bars (2988psi) and stop the pump. 
R - put the parking brake control switch (73GG) in the ON position. 
R - do a check for hydraulic leakage of the parking brake control valve 
R (102GG).
R (a) If the leakage is more than 20 cm3/min during the first six 
R minutes and more than 1 cm3/min after this time: 
R - replace the CTL VALVE-PARK BRK, ELEC (102GG) (Ref. AMM TASK 32-R 45-51-000-001) (Ref. PM 32455140000100).
R (b) If leakage is in the permitted tolerances: 
R - put the parking brake control switch (73GG) in the OFF 
R position. 
R - operate the manual depressurization pushbutton of the 
R relief-valve (3067GM) to release the accumulator pressure. 
R - remove the plug on the T fitting. 
R - connect the line on the T fitting.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞32-45-00∞∞∞∞∞∞∞∞∞∞Page 207
 Aug 01/05 CES
R (2) On the Yellow hydraulic system, pressurize the hydraulic reservoir 
R (Ref. AMM TASK 29-14-00-614-002). 
R - use the Yellow electric pump to pressurize the Yellow brake 
R accumulator (2582GM) to 206 bars (2988 psi) and stop the pump. 
R - put the parking brake control switch (73GG) in the ON position.
R (3) If the fault continues: 
R - put the parking brake control switch (73GG) in the OFF position. 
R - operate the manual depressurization pushbutton of the relief-valve 
R (3067GM) to release the accumulator pressure. on the Yellow 
R hydraulic system, depressurize the hydraulic reservoir (Ref. AMM 
R TASK 29-14-00-614-001). 
R - replace the SEL VALVE-ALTN BRK (99GG) (Ref. AMM TASK 32-43-51-000-R 001) (Ref. AMM TASK 32-43-51-400-001).
R (4) On the Yellow hydraulic system, pressurize the hydraulic reservoir 
R (Ref. AMM TASK 29-14-00-614-002). 
R - use the Yellow electric pump to pressurize the Yellow brake 
R accumulator (2582GM) to 206 bars (2988 psi) and stop the pump. 
R - put the parking brake control switch (73GG) in the ON position.
R (5) If the fault continues: 
R - put the parking brake control switch (73GG) in the OFF position. 
R - operate the manual depressurization pushbutton of the relief-valve 
R (3067GM) to release the accumulator pressure. 
R - on the Yellow hydraulic system, depressurize the hydraulic 
R reservoir (Ref. AMM TASK 29-14-00-614-001). 
R - replace the BRAKE RELIEF VALVE (3067GM) (Ref. AMM TASK 32-44-15-R 000-001) (Ref. AMM TASK 32-44-15-400-001).
R (6) On the Yellow hydraulic system, pressurize the hydraulic reservoir 
R (Ref. AMM TASK 29-14-00-614-002). 
R - use the Yellow electric pump to pressurize the Yellow brake 
R accumulator (2582GM) to 206 bars (2988 psi) and stop the pump. put 
R the parking brake control switch (73GG) in the ON position.
R (7) If the fault continues: 
R - put the parking brake control switch (73GG) in the OFF position. 
R - operate the manual depressurization pushbutton of the relief-valve 
R (3067GM) to release the accumulator pressure. 
R - on the Yellow hydraulic system, depressurize the hydraulic 
R reservoir (Ref. AMM TASK 29-14-00-614-001). 
R - replace the MANIFOLD (3016GM) (Ref. AMM TASK 32-44-17-400-001) 
R (Ref. AMM TASK 32-44-17-400-001).
R (8) On the Yellow hydraulic system, pressurize the hydraulic reservoir 
R (Ref. AMM TASK 29-14-00-614-002). 
R - use the Yellow electric pump to pressurize the Yellow brake 
R accumulator (2582GM) to 206 bars (2988 psi) and stop the pump. 
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 起落架 LANDING GEAR 2(62)