(a) Put a warning notice to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
 F 『 EEFF : ALL E Page 60173-11-50
 E E Feb 01/98 E E ECES E
 F 『
 E C F M E
 E E
 E 56-5B E
 E E
 (3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a warning notice to tell persons not to energize the FADEC 1(2).
 Subtask 73-11-50-010-056
 B. Open the fan cowl doors: (Ref. TASK 71-13-00-010-040)
 FOR 1000EM1
 437AL, 438AR
 FOR 1000EM2
 447AL, 448AR
 4. Procedure
_________
 Subtask 73-11-50-210-051
 A. Do the visual inspection of :
 -------------------------------------------------------------------------------INSPECT/CHECK MAXIMUM REMARKS SERVICEABLE LIMITS -------------------------------------------------------------------------------
1. All areas for :
 A. Cracks  Not serviceable Replace fuel return valve assembly (Ref. TASK 73-11-50-000-002) and (Ref. TASK 73-11-50-400-002)
 F 『 EEFF : ALL E Page 60273-11-50
 E E Feb 01/98 E E ECES E 5. Close-up
 F  『 
 E  C F M  E 
 E  E 
 E  56-5B  E 
 E  E
________ Subtask 73-11-50-410-055
 A. Close Access
 (1) Make sure that the work area is clean and clear of tool(s) and other items.
 (2) Close the fan cowl doors: (Ref. TASK 71-13-00-410-040)
 FOR 1000EM1
 437AL, 438AR
 FOR 1000EM2
 447AL, 448AR
 (3) Remove the warning notice(s).
 F 『 EEFF : ALL E Page 60373-11-50
 E E Feb 01/98 E E ECES E
 F  『 
 E  C F M  E 
 E  E
 E 56-5B E
 E E
 IDG OIL COOLER - REMOVAL/INSTALLATION
_____________________________________ TASK 73-11-60-000-002 Removal of the Integrated Drive Generator (IDG) Oil Cooler Assembly
 1. Reason for the Job
__________________
 Self Explanatory
 2. Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific caps and plugs No specific container 4L (1 USgal) No specific warning notice
 B. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
71-13-00-010-040 Opening of the Fan Cowl Doors 73-11-60-991-301 Fig. 401
 3. Job Set-up
__________ Subtask 73-11-60-941-052
 A. Safety Precautions
 (1) On the center pedestal, on the ENG panel 115VU:
(a) Put a warning notice to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
 F 『 EEFF : ALL E Page 40173-11-60
 E E Feb 01/98 E E ECES E
 F 『
 E C F M E
 E E
 E 56-5B E
 E E
 (3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a warning notice to tell persons not to energize the FADEC 1(2).
 Subtask 73-11-60-010-051
 B. Open the fan cowl doors: (Ref. TASK 71-13-00-010-040)
 FOR 1000EM1
 437AL, 438AR
 FOR 1000EM2
 447AL, 448AR
 4. Procedure
_________
 (Ref. Fig. 401/TASK 73-11-60-991-301)
 Subtask 73-11-60-020-051
 A. Remove the IDG oil cooler.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM 发动机燃油和控制 ENGINE FUEL AND CONTRO(77)