(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a warning notice to tell persons not to energize the FADEC 1(2).
Subtask 73-11-20-010-055
B. Open the fan cowl doors: (Ref. TASK 71-13-00-010-040)
FOR 1000EM1
437AL, 438AR
FOR 1000EM2
447AL, 448AR
4. Procedure
_________
Subtask 73-11-20-210-053
A. Inspect the servo fuel heater:
-------------------------------------------------------------------------------INSPECT/CHECK MAXIMUM REMARKS SERVICEABLE LIMITS -------------------------------------------------------------------------------
1. All areas for :
- Cracks. Not serviceable. Replace servo fuel heater assembly (Ref. TASK 73-11-20-000-002) and (Ref. TASK 73-11-20-400-002).
F 『 EEFF : ALL E Page 60273-11-20
E E Feb 01/98 E E ECES E 5. Close-up
F 『
E C F M E
E E
E 56-5B E
E E
________ Subtask 73-11-20-410-053
A. Close Access
(1) Make sure that the work area is clean and clear of tool(s) and other items.
(2) Close the fan cowl doors: (Ref. TASK 71-13-00-410-040)
FOR 1000EM1
437AL, 438AR
FOR 1000EM2
447AL, 448AR
(3) Remove the warning notice(s).
F 『 EEFF : ALL E Page 60373-11-20
E E Feb 01/98 E E ECES E
F 『
E C F M E
E E
E 56-5B E
E E
FUEL MANIFOLD - INSPECTION/CHECK
________________________________
TASK 73-11-30-200-002
Inspection/Check of the Fuel Manifold Assembly
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------
No specific warning notice
No specific access platform 1 m (3 ft. 3 in.)
B. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
70-51-00-230-002 Fluorescent-Penetrant Inspection-Portable-Water
Washable
71-13-00-010-040 Opening of the Fan Cowl Doors
71-13-00-410-040 Closing of the Fan Cowl Doors
R 73-11-40-000-001 Removal of the Fuel Nozzles R 73-11-40-400-001 Installation of the Fuel Nozzles 78-30-00-081-041 Make the Thrust Reverser Serviceable after Maintenance 78-30-00-481-041 Make the Thrust Reverser Unserviceable for
Maintenance
78-36-00-010-040 Opening of the Thrust Reverser Doors
78-36-00-410-040 Closing of the Thrust Reverser Doors
73-11-30-991-300 Fig. 601
73-11-30-991-301 Fig. 602
F 『 EEFF : ALL E Page 60173-11-30
E E Aug 01/02 E E ECES E
F 『
E C F M E
E E
E 56-5B E
E E
3. Job Set-up
__________
Subtask 73-11-30-941-051
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a warning notice to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a warning notice to tell persons not to energize the FADEC 1(2).
Subtask 73-11-30-010-052
B. Get Access
(1) Open the fan cowls doors (Ref. TASK 71-13-00-010-040):
FOR 1000EM1
437AL, 438AR
FOR 1000EM2
447AL, 448AR
(2) Put the access platform in position.
Subtask 73-11-30-040-051
C. Make the thrust reverser unserviceable (Ref. TASK 78-30-00-481-041).
Subtask 73-11-30-010-053
D. Open the thrust reverser doors (Ref. TASK 78-36-00-010-040):
FOR 1000EM1
451AL, 452AR
FOR 1000EM2
461AL, 462AR
F 『 EEFF : ALL E Page 60273-11-30
E E Feb 01/98 E E ECES E 4. Procedure
F 『 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320飞机维护手册 AMM 发动机燃油和控制 ENGINE FUEL AND CONTRO(50)