-------------------------------------------------------------------------------INSPECT/CHECK MAXIMUM REMARKS SERVICEABLE LIMITS -------------------------------------------------------------------------------
missing U-shaped
seal (removable)
R
R END OF SB 72-071
R
R G. Missing panel
R H. Loose bolts
R J. Subsurface linear
R impressions or
R wrinkles
R K. Voids
R
R
R
R
R L. Defects in the
R protective coating
R (initial Tedlar
R film, or paint)
R such as:
R (1) Missing
R
R (2) Defects
R (dents, nicks,
R tears,
R flaking) that
R let show the
R inner skin
R M. Inner skin
R defects, such as:
Not serviceable
Not serviceable
No limits
Five per panels, 2 in.
(50.8 mm) apart, 0.12 in. (3 mm) Dia max,
0.012 in. (0.3 mm) max depth
No limits
No limits new U-shaped seal(Ref. TASK 72-23-00-000-026) or (Ref. TASK 72-23-00-400-026)
Tighten bolts
Serviceable criteria applied on new parts
Serviceable criteria applied on new parts
Remove the loose material with a sharp blade
Remove the loose material with a sharp blade
F 『 EEFF : ALL E Page 66572-23-00
E E May 01/05 E E ECES E
F 『
E C F M E
E E
E 56-5B E
E E
-------------------------------------------------------------------------------INSPECT/CHECK MAXIMUM REMARKS SERVICEABLE LIMITS -------------------------------------------------------------------------------
R (1) Superficial
R defects
R (dents, nicks,
R tears, impact
R marks) not
R through the
R skin
R (2) Defects
R (tears,
R cracks,
R punctures)
R through the
R skin
5. Close-up________
Subtask 72-23-00-410-111
A. Close Access
No limits with a total surface area less than 4 square in. (2580 sq mm) per panel
Not serviceable Remove the loose material with a sharp blade
Replace panel(s)
(Ref. TASK 72-23-00-000-026) and (Ref. TASK 72-23-00-400-026)
(1) Make sure that the work area is clean and clear of tool(s) and other items.
(2) Close the thrust reverser doors (Ref. TASK 78-36-00-410-040): FOR 1000EM1 451AL, 452AR FOR 1000EM2 461AL, 462AR
Subtask 72-23-00-440-067
B. Make the thrust reverser serviceable (Ref. TASK 78-30-00-081-041).
Subtask 72-23-00-410-112
C. Close Access
(1) Close the fan cowl doors (Ref. TASK 71-13-00-410-040):
FOR 1000EM1
437AL, 438AR
FOR 1000EM2
447AL, 448AR
F 『 EEFF : ALL E Page 66672-23-00
E E May 01/05 E E ECES E F 『 E C F M E E E E 56-5B E E E (2) Remove the access platform(s).
(3) Remove the warning notice(s).
F 『 EEFF : ALL E Page 66772-23-00
E E May 01/05 ERE
ECES E
F 『
E C F M E
E E
E 56-5B E
E E
TASK 72-23-00-210-007
Visual Inspection of the Junction Box
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------
No specific warning notice
B. Consumable Materials
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
Material No. CP2242 USA MIL-A-46106A
RTV 732 (Ref. 70-30-00)
C. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
71-13-00-010-040 Opening of the Fan Cowl Doors
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM ENGINE 发动机 2(6)