-------------------------------------------------------------------------------INSPECT/CHECK MAXIMUM REMARKS SERVICEABLE LIMITS -------------------------------------------------------------------------------
missing U-shaped  
seal (removable)  
R  
R  END OF SB 72-071  
R  
R  G. Missing panel  
R  H. Loose bolts  
R  J. Subsurface linear  
R  impressions or  
R  wrinkles  
R  K. Voids  
R  
R  
R  
R  
R  L. Defects in the  
R  protective coating  
R  (initial Tedlar  
R  film, or paint)  
R  such as:  
R  (1) Missing  
R  
R  (2) Defects  
R  (dents, nicks,  
R  tears,  
R  flaking) that  
R  let show the  
R  inner skin  
R  M. Inner skin  
R  defects, such as:
Not serviceable 
Not serviceable 
No limits 
Five per panels, 2 in. 
(50.8 mm) apart, 0.12 in. (3 mm) Dia max, 
0.012 in. (0.3 mm) max depth 
No limits 
No limits new U-shaped seal(Ref. TASK 72-23-00-000-026) or (Ref. TASK 72-23-00-400-026) 
Tighten bolts 
Serviceable criteria applied on new parts 
Serviceable criteria applied on new parts 
Remove the loose material with a sharp blade 
Remove the loose material with a sharp blade 
F 『 EEFF : ALL E Page 66572-23-00
 E E May 01/05 E E ECES E
 F 『
 E C F M E
 E E
 E 56-5B E
 E E
 -------------------------------------------------------------------------------INSPECT/CHECK MAXIMUM REMARKS SERVICEABLE LIMITS -------------------------------------------------------------------------------
R  (1) Superficial  
R  defects  
R  (dents, nicks,  
R  tears, impact  
R  marks) not  
R  through the  
R  skin  
R  (2) Defects  
R  (tears,  
R  cracks,  
R  punctures)  
R  through the  
R  skin 
 5. Close-up________ 
 Subtask 72-23-00-410-111 
 A. Close Access
No limits with a total surface area less than 4 square in. (2580 sq mm) per panel 
Not serviceable Remove the loose material with a sharp blade 
Replace panel(s) 
(Ref. TASK 72-23-00-000-026) and (Ref. TASK 72-23-00-400-026)
(1) Make sure that the work area is clean and clear of tool(s) and other items.
(2) Close the thrust reverser doors (Ref. TASK 78-36-00-410-040): FOR 1000EM1 451AL, 452AR FOR 1000EM2 461AL, 462AR
 Subtask 72-23-00-440-067
 B. Make the thrust reverser serviceable (Ref. TASK 78-30-00-081-041).
 Subtask 72-23-00-410-112
 C. Close Access
 (1) Close the fan cowl doors (Ref. TASK 71-13-00-410-040):
 FOR 1000EM1
 437AL, 438AR
 FOR 1000EM2
 447AL, 448AR
 F 『 EEFF : ALL E Page 66672-23-00
 E E May 01/05 E E ECES E F 『 E C F M E E E E 56-5B E E E (2) Remove the access platform(s).
 (3) Remove the warning notice(s).
 F 『 EEFF : ALL E Page 66772-23-00
 E E May 01/05 ERE 
ECES E
 F 『
 E C F M E
 E E
 E 56-5B E
 E E
 TASK 72-23-00-210-007
 Visual Inspection of the Junction Box
 1. Reason for the Job
__________________
 Self Explanatory
 2. Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------
REFERENCE  QTY DESIGNATION
 -------------------------------------------------------------------------------
No specific  warning notice
 B. Consumable Materials
 -------------------------------------------------------------------------------
REFERENCE  DESIGNATION
 -------------------------------------------------------------------------------
Material No.  CP2242 USA MIL-A-46106A
 RTV 732 (Ref. 70-30-00)
 C. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE  DESIGNATION
 -------------------------------------------------------------------------------
71-13-00-010-040 Opening of the Fan Cowl Doors
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM ENGINE 发动机 2(6)