* acetone (Ref. 70-30-00)* white spirit (Ref. 70-30-00)* stoddard solvent (Ref. 70-30-00)* engine oil (Ref. 70-30-00) * ardrox 552 (Ref. 70-30-00) * turco ind 79 (Ref. 70-30-00) * mag-chem teksol (Ref. 70-30-00) * degreasol 99 R (Ref. 70-30-00) *
『
E 79-00-00Page 609
E May 01/05EE
F 『
E C F M E
E E
E 56-5B E
E E
-------------------------------------------------------------------------------
REFERENCE ------------------ DESIGNATION-------------------------------------------------------------
R mag-chem skysol (Ref. 70-30-00)
C. Expendable Parts
---------FIG.ITEM --------- --------------------------------------------------|DESIGNATION -------------------------------------------------- --------------------|IPC-CSN--------------------
10 O-ring 79-21-50 01 -090
D. Referenced Information
------------------REFERENCE -----------------------------------------DESIGNATION --------------------
-------------------------------------------------------------------------------
71-00-00-000-042 Removal of the Power Plant 71-00-00-400-042 Installation of the Power Plant 71-13-00-010-040 Opening of the Fan Cowl Doors 71-13-00-410-040 Closing of the Fan Cowl Doors 72-62-00-000-002 Removal of the Transfer Gearbox Module 72-62-00-400-002 Installation of the Transfer Gearbox Module 72-63-00-000-003 Removal of the Accessory Gearbox Assembly 72-63-00-400-003 Installation of the Accessory Gearbox Assembly 79-00-00-080-001 Removal of the Magnetic Bar from the Scavenge Screen
Plugs (IF OPTIONALLY INSTALLED) 79-00-00-281-003 Check of FWD, AFT Sump, AGB, and TGB scavenge screens 79-00-00-480-001 Installation of a Magnetic Bar in the Scavenge Screen
Plugs (OPTIONAL) 79-21-30-440-001 Resetting of the Visual Indicator 79-00-00-991-301 Fig. 601 79-00-00-991-304 Fig. 602 79-00-00-991-305 Fig. 603 79-00-00-991-306 Fig. 604
3. Job Set-up
__________
Subtask 79-00-00-941-055
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a warning notice to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
F 『 EEFF : ALL E Page 61079-00-00
E E May 01/05 E E ECES E
F 『
E C F M E
E E
E 56-5B E
E E
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a warning notice to tell persons not to energize the FADEC 1(2).
Subtask 79-00-00-010-055
B. Open the fan cowls doors: (Ref. TASK 71-13-00-010-040)
FOR 1000EM1
437AL, 438AR
FOR 1000EM2
447AL, 448AR.
4. Procedure
_________
Subtask 79-00-00-281-050
A. Inspection of the Electrical Master Chip Detector (EMCD)
(Ref. Fig. 601/TASK 79-00-00-991-301)
NOTE : If the EMCD is removed for inspection only, it is not necessary to
____
disconnect the lead connector.
(1) Remove the Electrical Master Chip Detector (EMCD) as follow:
(a) At the same time, push and turn the EMCD plug one quarter of a turn counterclockwise.
(b) Disengage the EMCD from its housing. 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320飞机维护手册 AMM OIL 滑油(11)