_ (Ref. TASK 28-00-00-910-001) when you do work in a fuel tank.
 (b)
 Equipment 1 Milliohmmeter - intrinsic safety (for test in the fuel tanks),
_ with the related leads and prods: - output test current: 0.2 amperes maximum
 -range: 500 milliohms minimum R - precision: better than plus or minus 10 % of the measured R value. R
 4. Procedure
_________
 Subtask 20-28-00-869-063
 A. Measurement of the Electrical Resistance CAUTION : MAKE SURE THAT YOU DO NOT CAUSE DAMAGE TO THE EQUIPMENT OR THE
_______
 STRUCTURE WHEN YOU USE SHARP-POINT PRODS.
 CAUTION : MAKE SURE THAT THE TEST EQUIPMENT IS CORRECTLY INSTALLED BEFORE
_______
 YOU MEASURE THE BONDING VALUES.
 (1)
 Connect the test equipment at the applicable locations (Ref. TASK 20-28-00-869-002).
 (2)
 Measure the resistance value.
 (3)
 Make sure that the measured values are not higher than the maximum permitted values (Ref. TASK 20-28-00-869-002).
 (4)
 Remove the test equipment.
 5. Close-up________  
R 
 Subtask 20-28-00-942-095  
R  A. Close Access 
R  (1) Make sure that the work area is clean and clear of tool(s) and other items. 
 TASK 20-28-00-720-008
R R  Check of the Electrical Bonding of the Different Components Installed on Composite Materials 
 1. Reason for the Job__________________ 
 Self Explanatory 
 2. Job Set-up Information______________________ 
 A. Fixtures, Tools, Test and Support Equipment 
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION ------------------------------------------------------------------------------- 
R R  No specific No specific  Megohmeter - 10 Megohms - 500 Volts - 1 mA (max.) Ohmmeter - 500 Kohms - 500 Volts - 1 mA (max.) 
 B. Referenced Information 
 -------------------------------------------------------------------------------REFERENCE DESIGNATION ------------------------------------------------------------------------------- 
R  20-28-00-869-002  Table of the Maximum Permitted Resistance Values  
3. Job Set-up__________ 
 Subtask 20-28-00-869-066  
R  A. Equipment  
R R  (1) Ohmmeter - 500 Kohms - 500 Volts - 1 mA (max.), with the related leads and prods.  
R R R (2) Megohmeter - 10 Megohms - 500 Volts - 1 mA (max.) with the related leads and prods. 
 4. Procedure
_________
 Subtask 20-28-00-420-086
 A. Measurement of the Electrical Resistance. CAUTION : MAKE SURE THAT YOU DO NOT CAUSE DAMAGE TO THE EQUIPMENT OR THE
_______
 STRUCTURE WHEN YOU USE SHARP-POINT PRODS.
 CAUTION : MAKE SURE THAT THE TEST EQUIPMENT IS CORRECTLY INSTALLED BEFORE
_______
 YOU MEASURE THE BONDING VALUES.
 (1)
 Connect the test equipment at the applicable locations (Ref. TASK 20-28-00-869-002).
 (2)
 Measure the resistance value.
 (3)
 Make sure that the measured values are not higher than the maximum permitted values (Ref. TASK 20-28-00-869-002).
 (4)
 Remove the test equipment.
 5. Close-up
________ Subtask 20-28-00-942-097
 A. Close Access
 (1) Make sure that the work area is clean and clear of tool(s) and other items.
 1EFF : ALL 1 20-28-00Page 523 1 1 Feb 01/03R 1 1 1CES 1
TASK 20-28-00-720-010
 Check of the Electrical Bonding of External Composite Panels with a CORAS
 Resistivity-Continuity Test Set
 1.
 Reason for the Job
__________________
 Self Explanatory
 2.
 Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------
REFERENCE  QTY DESIGNATION
 -------------------------------------------------------------------------------
QB31B 1 RESISTIVITY - CONTINUITY TEST SET R QB31B1 1 RESISTIVITY - CONTINUITY TEST SET
 B. Referenced Information
 -------------------------------------------------------------------------------
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM STANDARD PRACTICES-AIRFRAME(99)