_ (Ref. TASK 28-00-00-910-001) when you do work in a fuel tank.
(b)
Equipment 1 Milliohmmeter - intrinsic safety (for test in the fuel tanks),
_ with the related leads and prods: - output test current: 0.2 amperes maximum
-range: 500 milliohms minimum R - precision: better than plus or minus 10 % of the measured R value. R
4. Procedure
_________
Subtask 20-28-00-869-063
A. Measurement of the Electrical Resistance CAUTION : MAKE SURE THAT YOU DO NOT CAUSE DAMAGE TO THE EQUIPMENT OR THE
_______
STRUCTURE WHEN YOU USE SHARP-POINT PRODS.
CAUTION : MAKE SURE THAT THE TEST EQUIPMENT IS CORRECTLY INSTALLED BEFORE
_______
YOU MEASURE THE BONDING VALUES.
(1)
Connect the test equipment at the applicable locations (Ref. TASK 20-28-00-869-002).
(2)
Measure the resistance value.
(3)
Make sure that the measured values are not higher than the maximum permitted values (Ref. TASK 20-28-00-869-002).
(4)
Remove the test equipment.
5. Close-up________
R
Subtask 20-28-00-942-095
R A. Close Access
R (1) Make sure that the work area is clean and clear of tool(s) and other items.
TASK 20-28-00-720-008
R R Check of the Electrical Bonding of the Different Components Installed on Composite Materials
1. Reason for the Job__________________
Self Explanatory
2. Job Set-up Information______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
R R No specific No specific Megohmeter - 10 Megohms - 500 Volts - 1 mA (max.) Ohmmeter - 500 Kohms - 500 Volts - 1 mA (max.)
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
R 20-28-00-869-002 Table of the Maximum Permitted Resistance Values
3. Job Set-up__________
Subtask 20-28-00-869-066
R A. Equipment
R R (1) Ohmmeter - 500 Kohms - 500 Volts - 1 mA (max.), with the related leads and prods.
R R R (2) Megohmeter - 10 Megohms - 500 Volts - 1 mA (max.) with the related leads and prods.
4. Procedure
_________
Subtask 20-28-00-420-086
A. Measurement of the Electrical Resistance. CAUTION : MAKE SURE THAT YOU DO NOT CAUSE DAMAGE TO THE EQUIPMENT OR THE
_______
STRUCTURE WHEN YOU USE SHARP-POINT PRODS.
CAUTION : MAKE SURE THAT THE TEST EQUIPMENT IS CORRECTLY INSTALLED BEFORE
_______
YOU MEASURE THE BONDING VALUES.
(1)
Connect the test equipment at the applicable locations (Ref. TASK 20-28-00-869-002).
(2)
Measure the resistance value.
(3)
Make sure that the measured values are not higher than the maximum permitted values (Ref. TASK 20-28-00-869-002).
(4)
Remove the test equipment.
5. Close-up
________ Subtask 20-28-00-942-097
A. Close Access
(1) Make sure that the work area is clean and clear of tool(s) and other items.
1EFF : ALL 1 20-28-00Page 523 1 1 Feb 01/03R 1 1 1CES 1
TASK 20-28-00-720-010
Check of the Electrical Bonding of External Composite Panels with a CORAS
Resistivity-Continuity Test Set
1.
Reason for the Job
__________________
Self Explanatory
2.
Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------
QB31B 1 RESISTIVITY - CONTINUITY TEST SET R QB31B1 1 RESISTIVITY - CONTINUITY TEST SET
B. Referenced Information
-------------------------------------------------------------------------------
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM STANDARD PRACTICES-AIRFRAME(99)