| POINT LOCATION | TASK | MAX. PERMITTED |
| | REFERENCE | RESISTANCE VALUE|
--------------------------------------|----------------------------------------
R -------------------------------------------------------------------------------
R (6) Shielding conduits
R (Ref. TASK 20-28-00-720-005), (Ref. TASK 20-28-00-720-014)
R (a) The values given are for measurement between the adjacent primary
R metal structure and a metal part of the points that follow:
R -------------------------------------------------------------------------------
R | POINT LOCATION | TASK | MAX. PERMITTED |
R | | REFERENCE | RESISTANCE VALUE|
R --------------------------------------|----------------------------------------
R | - end of shielding conduits: | | |
R | | | |
R | DIA. between 9 and 12 mm (0.35 and| | |
R | 0.47 in.): | | |
R | . length less than or equal to | 20-28-00-720-005 | 5 milliohms |
R | 1 m (3.28 ft.) | | |
R | . length more than 1 m (3.28 ft.) | 20-28-00-720-005 | 10 milliohms |
R | | | |
R | DIA. between 14 and 20 mm (0.55 | | |
R | and 0.78 in.): | | |
R | . length less than or equal to | 20-28-00-720-005 | 5 milliohms |
R | 1.5 m (4.92 ft.) | | |
R | . length more than 1.5 m(4.92 ft.)| 20-28-00-720-005 | 10 milliohms |
R | | | |