‐ Wait 3 s if a normal cockpit control is used (unless a different time is indicated), or 1 s if a reset
button is used,
‐ Select the related normal cockpit control ON, or push the corresponding reset button,
‐ Wait 3 s for the end of the reset.
WARNING Do not reset more than one computer at the same time, unless instructed to do so.
The following table, lists the various computers for which manual reset capability is provided :
• On the overhead RESET panels
• On the system control panel.
A330/A340 FLIGHT CREW
OPERATING MANUAL
PROCEDURES
SUPPLEMENTARY PROCEDURES
ELECTRICAL
A330/A340 FLEET PRO-SUP-24 P 2/36
FCOM 19 AUG 10
For each computer, effects and/or precaution in case of reset (if any) are also listed.
‐ A computer reset has to be attempted when :
• recommended by an ECAM procedure or
• recommended by a paper procedure.
‐ In all other circumstances, where a failure is suspected or detected, there is no specific
recommendations as to whether a reset should be performed or not, except those where a reset is
specifically forbidden.
‐ Before doing any reset that is not asked for by ECAM, or paper checklist,Refer to QRH/ABN-80
Computer Reset - General to ensure that it is not forbidden.
Manual reset on ground triggers complete power up test.
The number of reset attempt is not limited.
A330/A340 FLIGHT CREW
OPERATING MANUAL
PROCEDURES
SUPPLEMENTARY PROCEDURES
ELECTRICAL
A330/A340 FLEET PRO-SUP-24 P 3/36
FCOM 19 AUG 10
COMPUTER RESET TABLE
Applicable to:
ATA EQUIPMENT MANUAL RESET
OVHD
RESET Panel
System
Control Panel
REMARKS
PACK CONT 2
ZONE CONT 1
AEVC 1
NIL
VENT CONT
2
If, in flight, the CAB REST SMOKE warning has been
temporarily displayed and identified as a false warning,
crew rest compartment ventilation may be recovered by
resetting both VENT controller channels (simultaneously
pull both ventilation controller RESET pb for at least 5 s,
then push them).
21
CPC 2 To force a CPC changeover:
‐ MODE SEL (MAN)
AFTER 3 s:
‐ MODE SEL (AUTO)
The inactive CPC may then be reset (check the CAB
PRESS ECAM SD page).
FCU
2
Do not reset when PART FCU is displayed as an inop
system.
‐ On ground : The FCU has to be reconfigured after
reset.
‐ In flight : Check FCU targets after reset.
Following a total FCU loss, targets are selected
targets.
FMGEC and FM
4
• FMGEC or FM resets results in onside AP
disconnection (if engaged)
• Resynchronization of both FMs will occur after a reset
sequence, with associated messages on the MCDU
and ND :
‐ PLEASE WAIT
‐ MAP NOT AVAIL
• It is recommended to use FMGEC R/B, rather than FM
R/B.
22
MCDU BRT OFF CTL In case the MCDU is blank or locked, Refer to STLO-22
MCDU LOCKED OR BLANKED .
To be continued on next page
A330/A340 FLIGHT CREW
OPERATING MANUAL
PROCEDURES
SUPPLEMENTARY PROCEDURES
ELECTRICAL
A330/A340 FLEET PRO-SUP-24 P 4/36
FCOM 19 AUG 10
Continued from previous page
CIDS 2 In the event of active CIDS reset (usually CIDS 1
when both are operative), a complete power-up test is
performed.
‐ In flight, test lasts about 20 s:
• The cabin light comes on at full intensity.
If selected, dimming is lost and must be reselected
after the test.
• PA, CALL and INTERPHONE functions are
interrupted and have to be reselected after the test.
• FAP cabin temperature corrections are lost, and
have to be reselected after the test.
‐ On ground, test lasts about 80 s, and includes
additionally:
• a sequencial cabin loudspeakers test (triggers a
tone for about 10 s).
• the cabin light might flash shortly. Dimming
selection is lost (as in flight)
ACP/AMU 2 NIL
23
RMP ON/OFF CTL In case of freezing of one RMP (impossibility to
interchange the ACTIVE and STBY radio navigation or
communication frequencies,...), all the RMP’s have to be
reset, one after the other, to recover a normal operation.
In order to be reset, RMP’s must be switched off at least
5 s by using the ON/OFF selector on the RMP control
panels.
24 GPCU 2 pb on
ELEC panel
GPCU reset may be attempted, if AVAIL and ON lights
do not light up.
1. Press once the affected EXT A(B) pb sw to reset the
functions of GPCU.
2. Switch ON the external power unit sw to reset the
GPU.
3. Check AVAIL light is ON and press the EXT A(B) pb
 
中国航空网 www.aero.cn