180  BACC10HS04  . CLAMP  2 
185  BACC10GT2-04  . CLAMP SHELL  4 
190  BACS12HN3U9  . SCREW  2 
195  BACN10YR3C  . NUT  2 
200  NAS1149C0332R  . WASHER  2 

71-00-02
 
PW2000 SERIES ENGINES


757
POWERPLANT BUILDUP MANUAL

FIGURE 8-1
FUEL FLOW TRANSMITTER INSTALLATION

REF QEC TASK NO.: 8
REF DWG: 332N3460

71-00-02
P/P BUILDUP FIGURE 8-1 Page 1 May 05/2009
 


Fuel Flow Transmitter Installation
Figure 8-1 (Sheet 1)

71-00-02
 


ITEM NO.  PART NUMBER  NOMENCLATURE  UC  QTY 
8-1  FUEL FLOW TRANSMITTER INSTALLATION (FIGURE 8-1, SHEET 1) POSITION O-RINGS (5) ON FUEL LINES. LOOSEN FORWARD (FUEL IN) LINE AT B-NUT ABOVE BIFURCATION, THEN POSITION TRANSMITTER (10) WITH LOCATING PIN AT TWELVE (12:00) O’CLOCK POSITION AND SECURE TO FUEL OUT LINE USING ITEMS (15 THRU 30). WHEN INSTALLING BRACKET (15) INSTALL WITH WASHER (30) ON AFT SIDE OF BRACKET (15) UNDER BOLT (25). 
5  M25988-3-217  . O-RING  2 
10  79-217-33  . FUEL FLOW XMTR (V08748) (BOEING S347T001-17)  VEN  -
10  S347T001-17  . TRANSMITTER  1 
15  332N3903-87  . BRACKET  1 
20  BACB30LE4HU8  . BOLT (USED WITH SAFETY CABLE)  2 
20  NAS6704HU8  . BOLT (USED WITH LOCKWIRE)  OPT  -
25  BACB30LE4HU5  . BOLT (USED WITH SAFETY CABLE)  2 
25  NAS6704HU5  . BOLT (USED WITH LOCKWIRE)  OPT  -
30  BACW10BP4ACU  . WASHER SECURE TRANSMITTER (10) TO FUEL IN LINE USING ITEMS (40 THRU 50). TIGHTEN FORWARD (FUEL IN) LINE AT B-NUT ABOVE BIFURCATION. INSTALL SAFETY CABLE OR LOCKWIRE TO BOLTS (20, 25, 40, 45).  2 
40  BACB30LE4HU4  . BOLT (USED WITH SAFETY CABLE)  2 
40  NAS6704HU4  . BOLT (USED WITH LOCKWIRE)  OPT  -
45  BACB30LE4HU2  . BOLT (USED WITH SAFETY CABLE)  2 
45  NAS6704HU2  . BOLT (USED WITH LOCKWIRE)  OPT  -
50  BACW10BP4ACU  . WASHER  4 

71-00-02
 
PW2000 SERIES ENGINES


757
POWERPLANT BUILDUP MANUAL

FIGURE 8-2
14TH STAGE SURGE BLEED DUCT
INSTALLATION

REF QEC TASK NO.: 8
REF DWG: 332N3750

71-00-02
P/P BUILDUP FIGURE 8-2 Page 1 May 05/2009
 


14th-Stage Surge Bleed Duct Installation
Figure 8-2 (Sheet 1)

71-00-02
 

ITEM NO.  PART NUMBER  NOMENCLATURE  UC  QTY 
8-2  14TH-STAGE SURGE BLEED DUCT INSTALLATION (FIGURE 8-2, SHEET 1) POSITION DUCT ASSY (5) BY ALIGNING DUCT ASSY BOLT FLANGE TO SURGE BLEED VALVE FLANGE AND PLACING E-SEAL (10) BETWEEN FLANGES. SECURE DUCT TO VALVE USING BOLTS (15 AND 20), WASHERS (25), AND NUTS (30). INSTALL WASHERS WITH CSK TOWARDS BOLT HEAD. DO NOT TIGHTEN. 
 