2.
Power EGPWC and PC and start WinVIEWS.
3. With WinVIEWS active in the Terminal Mode, Configuration sub-mode commands are available for the programming purpose. Type “CFG” at the prompt. At this point, the CFG > prompt is displayed and the program and EGPWC are ready for entering the program command and data string. “HELP” or “?” will display a list of the commands and their description. “CUW” is the necessary command for entering the identified ID’s for each category.
4. Using the Category ID’s chosen from the ICD (refer to completed Table 5.2), create a command string with the following structure:
CUW 0/15 # # # # # # # # # # # # # # #/
.
CUW<space>0 is the command and version number. CUW writes the category ID’s defined by version 0 definition (0 is the only version currently available) to the Configuration Module via the EGPWC without a CRC (checksum) value attached (this is generated by the EGPWC when the data is transmitted).
.
/15 indicates the beginning of the data string (/) with 15 being the total number of categories to follow.
.
<space><Cat 1 ID#><space><Cat 2 ID#>…<Cat 15 ID#>/ - each Cat ID # is the chosen ID for the associated category with the first being category 1 and the last being category 15 in order. The following slash indicates the end of the data.
Note: If 15 ID’s don’t follow “/15”, the error message “Invalid Parameter. Not enough category ID’s. Configuration update failed, please try again” will be given. The value entered for each category must be an available ID for the associated category or a similar error message will be given. If the number of categories provided is less than 15 (e.g., “/8 # …#/” with eight ID’s defined), then the remaining categories (9 through 15) will be set to 0.
5. After completing the data string as defined above, pressing ENTER results in a question; “Confirm this data reflects configuration to be programmed (Y/N)”. Pressing the Y key sends the data to the EGPWC to write to the Configuration Module. Following the writing of the Configuration Module the EGPWC is automatically rebooted in order for the configuration to take affect.
Note: If when the ENTER key is pressed the question response is not given (cursor just moves to the next line), pressing any character key should provide the proper response.
Pressing the N key results in the message “Command aborted – No configuration module change has been made”. If necessary, revise the data to correct or change as necessary and continue as above. The backspace key can be used to make corrections.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:增强型近地警告系统 Enhanced Ground Proximity Warning 航线维护手册 Systems Line Maintenance Manual(44)