XFER COMP LED is extinguished.
.
XFER FAIL LED is extinguished.
5.
Verify that the PCMCIA Card has its Write Protect Function Selector in the OFF position (see Figure 9.2).
NOTE: The PCMCIA Card Write Protect Selector is fragile and should be moved only with the minimum amount of force.
6.
Insert PCMCIA Card into the PCMCIA Card slot. For the MK V or MK VII, ensure the notch on the bottom of the PCMCIA Card is in the down position. Push the card in carefully until the PUSH TO EJECT button on the front Panel is fully extended. This will be when the face of the button is nearly level with the rear of the inserted PCMCIA Card. For the MK VI or MK VIII, the label on the card and on the Smart Cable should both be oriented in the same direction. The PCMCIA Card will only insert about half the card length.
CAUTION: Excessive force will damage the internal connector.
7.
While loading is in progress, the IN PROG LED illuminates and the COMPUTER OK LED turns OFF.
8.
When loading is complete, the IN PROG LED will turn OFF and the XFER COMP LED will turn ON. NOTE: This operation should require no more than 10 minutes. NOTE: If the XFER FAIL LED turns ON instead of the XFER COMP LED, then a different Flight History
Download PCMCIA Card must be obtained from Honeywell for the Data Download.
9.
Remove the PCMCIA Card, For the MK V or MK VII, depress the PUSH TO EJECT button on the EGPWC front panel. For the MK VI or MK VIII, carefully grasp the card and pull from the Smart Cable.
NOTE: The EGPWS should automatically return to its normal operating mode upon removal of the card.
10.
Verify that the COMPUTER OK LED illuminates (allow up to 3 minutes for the light to come on).
11.
Procedure is complete. Close the EGPWC front panel door or disconnect the Smart Cable as appropriate. NOTE: Flight History Download Cards can only be used once.
4.3.3 TRANSCRIPTION OF THE PCMCIA CARD.
For transcription of a Flight History Download Card, return the card and Customer Worksheet to: Honeywell
P.O. Box 97001 Attn: EGPWS Dept., Administrative Assistant, Certification Group M/S L2J 15001 N.E. 36th Street Redmond, WA USA 98052 Phone 1-800-813-2099 FAX: (425) 885-2994
4.4 PROGRAMMING THE CONFIGURATION MODULE (MK VI AND MK VIII ONLY)
Programming the EGPWS Configuration Module is accomplished using WinVIEWS on a PC connected to the EGPWC via the RS-232 interface. Prior to this activity, the necessary and desired configuration should be determined based on the MK VI/MK VIII Interface Control Document (ICD document number 993-1176-401). Utilize a copy of Table 5.2 in the ICD for recording the associated installation Category ID information.
For programming the Configuration Module, the following procedure is used: