THE FOLLOWING EXTERNAL FAULTS ARE AVAILABLE IN LEVEL 2 SELF-TEST:  
Enunciation:  “FLAP ANGLE UNREASONABLE”  
Probable Cause:  Electrical short at the flap discrete input(s).  
Action:  Verify wiring from the flap-input discrete(s).  
Description:  SELF-TEST INVALID (WinViews ONLY)  
Probable Cause:  Electrical short at the Self-Test input.  
Action:  Verify wiring from the Self-Test discrete.  
Enunciation:  “MOMENTARY TERRAIN SELECT 1 (or 2) INVALID”  
Probable Cause:  Electrical short at the Terrain Select inputs.  
Action:  Verify wiring from the terrain “ON” switches.  
Enunciation:  “PROGRAM PIN READ ERROR”  
Probable Cause:  Wiring error to the program pins.  
Action:  Verify wiring to each program pin.  
Enunciation:  “CALLOUTS OPTION INVALID”  
Probable Cause:  Wiring error to the Callout Options program pins.  
Action:  Verify wiring to the Callout Options program pins.  
Enunciation:  “AUDIO MENU INVALID”  
Probable Cause:  Wiring error to the Audio Menu program pins.  
Action:  Verify wiring to the Audio Menu program pins.  
Enunciation:  “PROGRAM PIN <XX> INVALID” (where XX is a number)  
Probable Cause:  Invalid option selected.  
Action:  Verify wiring to all program pins.  
Description:  “CONFIGURATION MODULE READ ERROR” (WinViews ONLY)  
Probable Cause:  The Configuration Module is faulty.  
Action:  Cycle power to the EGPWC.  If the problem persist, reprogram the Configuration Module. IF the condition persist, replace the Program Module.  See Appendix C.  
Description:  “CONFIGURATION MODULE NOT PROGRAMMED” (WinViews ONLY)  
Probable Cause:  The Configuration Module is new, or never has been programmed.  
Action:  Reprogram the Configuration Module.  See Appendix C.  
 