3.8.5 +28V LANDING FLAP OR FLAP OVERRIDE DISCRETE 
Type:  Supplied by Flap or Flap selector handle switch.  This input can be paralleled with, or used exclusively by a Flap Override Switch if an alternate source of Flap Position is used. 
Signal Status:  Landing Flaps or Not Landing Flaps 
Fault monitoring: Indication of landing flaps selected for more than 60 seconds at airspeeds above 250 knots will result in a flap switch fault which will cause a GPWS INOP indication. 
Note: This can be caused either by a flap switch fault or by the Flap Override switch being left in the on position. 
Level 6 Audio readout 
+28 V Landing Flaps Discrete 
Selected => “28V Flaps Selected” 
or Flap Override 
Not Selected => “28V Flaps Not Selected” 
Note: If Flap Reversal Program Pin is enabled for MK VII EGPWC, the Audio readout will be: 
Level 6 Audio readout  
GND Landing Flaps Discrete  Selected =>  “Flaps Selected”  
or Flap Override  Not Selected =>  “Flaps Not Selected” 
3.8.6 FLAP POSITION DISCRETES 
Up to four flap position discretes are typically supplied from the flap selector handle switch. 
Type: Supplied by Flap selector handle switch. 
Signal Status: Flap position selected. 
Fault monitoring: Depending on the installation, activation of more than one, or none of these discretes for more than
30 seconds will result in a Flap Unreasonable indication. 
Level 6  Audio readout  
Flap Position Discrete #1  Selected => Not Selected =>  “Flap 1 True” “Flap 1 False”  
Flap Position Discrete #2  Selected => Not Selected =>  “Flap 2 True” “Flap 2 False”  
Flap Position Discrete #3  Selected => Not Selected =>  “Flap 3 True” “Flap 3 False”  
Flap Position Discrete #4  Selected => Not Selected =>  “Flap 4 True” “Flap 4 False” 
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:增强型近地警告系统 Enhanced Ground Proximity Warning 航线维护手册 Systems Line Maintenance Manual(34)