Enunciation:  “PROGRAM PIN PARITY ERROR” (MK V or MK VII only) 
Probable Cause:  Wiring error in the program pins. 
Action:  Verify wiring to each program pin.  Verify ODD parity selected. 
Enunciation:  “AIRCRAFT TYPE INVALID” (MK V or MK VII only) 
Probable Cause:  Wiring error to the Aircraft Type program pins. 
Action:  Verify wiring to the Aircraft Type program pins. 
Enunciation:  “CONFIGURATION TYPE INVALID” (MK VI or MK VIII only) 
Probable Cause:  The programmed configuration type is not a valid configuration. 
Action:  Correct and reprogram the Configuration Module (see Maintenance Practices section) 
Enunciation:  “AIRCRAFT CONFIGURATION DATA BASE FAILED” (MK V or MK VII only) 
Probable Cause:  EGPWC internal Configuration database error. 
Action:  Pull power to the EGPWS for one minute and cycle power to clear all potential faults before removing  or replacing the EGPWC for repair (see Removal/Installation section) 
Enunciation:  “ APPLICATION DATA BASE FAILED” (MK VI or MK VIII only) 
Probable Cause:  EGPWC internal Application database error. 
Action:  Pull power to the EGPWS for one minute and cycle power to clear all potential faults before removing  or replacing the EGPWC for repair (see Removal/Installation section) 
Enunciation:  “AIRCRAFT CONFIGURATION DATA BASE CRC FAILED” (MK V or MK VII only) 
Probable Cause:  EGPWC internal configuration database error. 
Action:  Pull power to the EGPWS for one minute and cycle power to clear all potential faults before removing  or replacing the EGPWC for repair (see Removal/Installation section) 
Enunciation:  “ APPLICATION DATA BASE CRC FAILED” (MK VI or MK VIII only) 
Probable Cause:  EGPWC internal Application database error. 
Action:  Pull power to the EGPWS for one minute and cycle power to clear all potential faults before removing  or replacing the EGPWC for repair (see Removal/Installation section) 
Enunciation:  “CONFIGURATION MODULE READ ERROR” (MK VI or MK VIII only) 
Probable Cause:  The Configuration Module is faulty. 
Action:  Verify Configuration Module connections.  Cycle power to the EGPWC.  If the problem persists, reprogram the Configuration Module.  IF the condition persist, replace the Configuration Module.  See Removal/Installation section. 


POSSIBLE SELF-TEST PREAMBLE RESULTS 
Enunciation:  “CONFIGURATION MODULE NOT PROGRAMMED” (MK VI or MK VIII only) 
Probable Cause:  The Configuration Module is not programmed. 
 