(1) If the TROUBLE SHOOTING DATA page gives the maintenance message VACU GEN:
- do a check of the electrical connections 37MG/A and 37MG/B.
(2) If the electrical connections are correct:
 - replace the GENERATOR-VACUUM (37MG) (Ref. AMM TASK 38-31-64-000-001) and (Ref. AMM TASK 38-31-64-400-001). 
R **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
 C. Do the test as given in Para. 3.
 (1) make sure that the vacuum toilet system operates correctly (Ref. AMM TASK 38-31-00-710-009).
(2) After the subsequent flight, make sure that the fault does not continue.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-105, 151-199, ∞∞38-31-00∞∞∞∞∞∞∞∞∞∞Page 202
 201-299, May 01/05 CES
 INTENTIONALLY BLANK
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R ∞∞38-31-00∞∞∞∞∞∞∞∞∞∞Page 203
 MCDU Display Figure 201/TASK 38-31-00-991-001- 12 (SHEET 1)
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-105, 151-199, ∞∞38-31-00∞∞∞∞∞∞∞∞∞∞Page 204
 201-299, May 01/05 CES
 MCDU Display Figure 201/TASK 38-31-00-991-001- 22 (SHEET 2)
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-105, 151-199, ∞∞38-31-00∞∞∞∞∞∞∞∞∞∞Page 205
 201-299, May 01/05 CES
TASK 38-31-00-810-804
 Liquid Level Transmitter (40MG) Failure
 1. Possible Causes
_______________
 - XMTR-LEVEL PHASE OFF (40MG)
 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 38-31-00-710-009 Operational Test of the Toilet Unit AMM 38-31-00-710-009 Operational Test of the Toilet Unit AMM 38-31-00-740-001 BITE Test of the Vacuum Toilet System AMM 38-31-62-000-001 Removal of the Liquid Level Transmitter (40MG) AMM 38-31-62-400-001 Installation of the Liquid Level Transmitter (40MG) 38-31-00-991-001 Fig. 201
 3. Fault Confirmation
__________________
 A. Do the operational test of the vacuum toilet system (Ref. AMM TASK 38-31-00-710-009).
 B. Do the bite test (Ref. AMM TASK 38-31-00-740-001).
 4. Fault Isolation
_______________
 **ON A/C 151-199, 210-299,
 A. If the operational test is OK:
 - Refer to the trouble shooting data of the bite test.
 (Ref. Fig. 201/TASK 38-31-00-991-001)
(1) If the TROUBLE SHOOTING DATA page gives the maintenance message LIQD LVL XMTR:
- clean and fully dry the inside of the differential pressure vent line.
(2) If the fault continues:
- do a check of the electrical connections of the small connector 40MG/A.
(3) If the electrical connections are OK:
 - replace the XMTR-LEVEL PHASE OFF (40MG), (Ref. AMM TASK 38-31-62-000-001) and (Ref. AMM TASK 38-31-62-400-001).
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-105, 151-199, ∞∞38-31-00∞∞∞∞∞∞∞∞∞∞Page 206
 201-299, May 01/05 CES
R **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
 B. If the test gives a different maintenance message, you can find the related trouble shooting procedure in the applicable Page Block 101.
 - Refer to the CFDS-TROUBLE SHOOTING DATA page.
 (Ref. Fig. 201/TASK 38-31-00-991-001)
 C. Test
 (1) Do the operational test of the vacuum toilet system and make sure it operates correctly (Ref. AMM TASK 38-31-00-710-009).
(2) After the subsequent flight, make sure that the fault does not continue.