(2) Make sure that the potable water system is pressurized (Ref. AMM TASK 38-10-00-614-001).
4. Fault Isolation
_______________
A. If you cannot pressurize the potable water system:
- do a check and make sure that no air flows from the VALVE-OVERFLOW (8MP).
(1) If the over-flow valve 8MP is not closed:
- do a check and adjust the Fill limit switch 5MP as necessary.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-149, 201-299, ∞∞38-12-00∞∞∞∞∞∞∞∞∞∞Page 201
May 01/05 CES
(2) If the fault continues:
- do a check and make sure that the Control cable 3260MM operates freely, if not replace (Ref. AMM TASK 38-14-48-000-001) and (Ref. AMM TASK 38-14-48-400-001).
(3) If the fault continues:
- replace the VALVE-OVERFLOW (8MP), (Ref. AMM TASK 38-14-44-000-001) and (Ref. AMM TASK 38-14-44-400-001).
(4) If the fault continues:
- do a check and repair the aircraft wiring between the: CB 1MP and the connector A/C VALVE-OVERFLOW (8MP), (Ref. ASM 38-14/00).
5. Close-up
________
A. After the subsequent flight, make sure that the fault does not continue.
QUANTITY INDICATING - FAULT ISOLATION PROCEDURES
________________________________________________
TASK 38-13-00-810-801
Water Quantity Indication Failure
1. Possible Causes
_______________
- GAUGE-CONTENTS (6MA)
- XMTR-QUANTITY (3MA)
- limit switch 5MA
- aircraft wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 38-13-00-710-001 Operational Test of the Quantity Indicating System AMM 38-13-00-710-002 Operational Test of the Door Limit Switch 5MA AMM 38-13-11-000-001 Removal of the Quantity Transmitter 3MA AMM 38-13-11-400-001 Installation of the Quantity Transmitter 3MA AMM 38-13-16-000-001 Removal of the Water Service-Panel Door-Switch (5MA) AMM 38-13-16-400-001 Installation of the Water Service-Panel Door-Switch
(5MA) AMM 38-13-21-000-001 Removal of the Quantity Indicator 6MA AMM 38-13-21-400-001 Installation of the Quantity Indicator 6MA AMM 38-14-00-710-001 Operational Test of the Potable Water Drain-System ASM 38-13/00
3. Fault Confirmation
__________________
R **ON A/C 001-049, 051-099, 101-149, 201-299,
A. Test.
(1) Do a test of the Quantity Indication System (Ref. AMM TASK 38-13-00-710-001).
(2) Do a test of the Water Draining (Dump) (Ref. AMM TASK 38-14-00-710-001).
R **ON A/C 151-199, 301-399, 401-499,
A. Test.
(1) Do a test of the Quantity Indicating System (Ref. AMM TASK 38-13-00-710-001).
**ON A/C ALL
4. Fault Isolation
_______________
A. If the test gives a different maintenance message, you can find the related trouble shooting procedure in the applicable Page Block 101.
B. If there is no quantity indication (no LED illumination/quantity indicator) on the FORWARD ATTENDANT PANEL 120RH/SERVICE PANEL 2023VU: - open and close the circuit breaker 1MA.
(1) If the fault continues:
- do a check of the doorlimit switch 5MA, (Ref. AMM TASK 38-13-00-710-002).
(2) If the fault continues:
- replace the door limit switch 5MA (Ref. AMM TASK 38-13-16-000-001) and (Ref. AMM TASK 38-13-16-400-001).
(3) If the fault continues:
- replace the GAUGE-CONTENTS (6MA), (Ref. AMM TASK 38-13-21-000-001) and (Ref. AMM TASK 38-13-21-400-001).
(4) If the fault continues:
- replace the XMTR-QUANTITY (3MA), (Ref. AMM TASK 38-13-11-000-001) and (Ref. AMM TASK 38-13-11-400-001).
(5) If the fault continues:
- do a check and repair the aircraft wiring between the: CB 1MA and the connector A/C XMTR-QUANTITY (3MA), (Ref. ASM 38-13/00).
C. Do the test as given in paragraph 3. A.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞38-13-00∞∞∞∞∞∞∞∞∞∞Page 202
Aug 01/05 CES
TASK 38-13-00-810-803 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320 Trouble Shooting Manual 排故手册 WATER/WASTE(7)