**ON A/C ALL
TASK 38-31-00-810-854
Vacuum Pressure of the Vacuum System is Too Low
1. Possible Causes
_______________
- GENERATOR-VACUUM (37MG)
- toilet drain lines
- tank drain line
- component of the vacuum toilet system
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 38-30-00-010-002 Removal of the Toilet Drain Lines AMM 38-30-00-410-002 Installation of the Toilet Drain Lines AMM 38-31-00-790-002 Leak Test of the Vacuum Toilet System AMM 38-31-64-000-001 Removal of the Vacuum Generator 37MG AMM 38-31-64-400-001 Installation of the Vacuum Generator 37MG AMM 38-31-76-000-001 Removal of the Flush Line Check Valves 3322MM/3323MM AMM 38-31-76-400-001 Installation of the Flush Line Check Valves
3322MM/3323MM
3. Fault Confirmation
__________________
A. Fault Confirmation Test
(1) Do the leak check of the Vacuum Toilet System (Ref. AMM TASK 38-31-00-790-002).
4. Fault Isolation
_______________
A. If the required negative differential pressure (Ref. to the GRAPH 1 and GRAPH 2 in figure 503 of the AMM TASK 38-31-00-790-002) is lower than the measured value:
- Examine the toilet drain lines for leaks with the vacuum system under pressure.
(1) If you find leaks, repair or replace the defective toilet drain lines (Ref. AMM TASK 38-30-00-010-002) and (Ref. AMM TASK 38-30-00-410-002).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞38-31-00∞∞∞∞∞∞∞∞∞∞Page 279
May 01/05R CES
(2) If the fault continues:
- Examine the tank drain line for leaks, if leaks are found:
- Repair or replace the tank drain line, (Ref. AMM TASK 38-31-76-000-001) and (Ref. AMM TASK 38-31-76-400-001).
(3) If you have replaced a component of the vacuum toilet system:
- Examine the installed component(s) for the correct installation.
- Make sure that the component(s) does (do) not leak.
(4) If the fault continues:
- Replace the GENERATOR-VACUUM (37MG), (Ref. AMM TASK 38-31-64-000-001) and (Ref. AMM TASK 38-31-64-400-001).
B. Test
(1) Do the test given in para. 3.
(2) Make sure that the vacuum toilet system operates correctly.
R **ON A/C 106-149, 301-399, 401-499,
TASK 38-31-00-810-855
MCDU Shows Waste Tank Level 1% although the Waste Tank is Empty (0%)
1. Possible Causes
_______________
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 38-31-00-710-009 Operational Test of the Toilet Unit
AMM 38-31-00-740-001 BITE Test of the Vacuum Toilet System
3. Fault Confirmation
__________________
A. Do a test of the vacuum toilet system (Ref. AMM TASK 38-31-00-710-009).
B. Do the procedure to get access to the CFDS SYSTEM REPORT/TEST menu PAGE (Ref. AMM TASK 38-31-00-740-001).
4. Fault Isolation
_______________
A. If the MCDU gives the maintenance message WASTE TANK LEVEL 1%:
- select the WATER/WASTE page on the FAP to get the real waste tank level.
B. Do the procedure to get access to the CFDS SYSTEM REPORT/TEST menu PAGE (Ref. AMM TASK 38-31-00-740-001).
TASK 38-31-00-810-856
CIDS gives Spurious Water/Waste Failure Messages
1. Possible Causes
_______________
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 23-73-00-740-010 Interface and Power-Up Test of the Cabin
Intercommunication Data System (CIDS) via the CFDS AMM 38-31-00-710-009 Operational Test of the Toilet Unit AMM 38-31-00-740-001 BITE Test of the Vacuum Toilet System
中国航空网 www.aero.cn