 Potable-Water Service Panel 2023VU Indication Light(s) Failure
 1. Possible Causes
_______________
 - lamp

 - aircraft wiring


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
AMM 38-13-00-960-001 Indication Lamps Replacement
 ASM 38-13/01

 3. Fault Confirmation
__________________
 A. Do the self-test (push to test) of the indication lamp, the light must come ON.
 4. Fault Isolation
_______________
 A. If the light does not come ON:
 - Replace the lamp (Ref. AMM TASK 38-13-00-960-001).
 (1) If the fault continues:
 - Do a check and repair the aircraft wiring (Ref. ASM 38-13/01). R B. Do the test given in para. 3.


 QUANTITY INDICATING - TASK SUPPORTING DATA
__________________________________________


 Potable Water Distribution - Schematic Figure 301 (SHEET 1)
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-149, 201-299, ∞∞38-13-00∞∞∞∞∞∞∞∞∞∞Page 302
 May 01/05 CES


 Potable Water Distribution - Schematic Figure 301 (SHEET 2)
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-149, 201-299, ∞∞38-13-00∞∞∞∞∞∞∞∞∞∞Page 303
 May 01/05 CES


 Potable Water Distribution - Schematic
 Figure 301A

 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 151-199, 301-399, 401-499, ∞∞38-13-00∞∞∞∞∞∞∞∞∞∞Page 304
 Aug 01/05 CES


 WATER DRAINING (DUMP) - FAULT ISOLATION PROCEDURES
__________________________________________________ TASK 38-14-00-810-801 Potable-Water Service panel 2023VU Indication Light(s) Failure
 1. Possible Causes
_______________
 - lamp

 - aircraft wiring


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 38-14-00-960-001 Indication Lamp Replacement ASM 38-14/01
 3. Fault Confirmation
__________________
 A. Do the self-test (push to test) of the indication lamp, the light must come ON.
 4. Fault Isolation
_______________
 A. If the light does not come ON:
 - Replace the lamp (Ref. AMM TASK 38-14-00-960-001).
 (1) If the fault continues:
 - Do a check and repair the aircraft wiring (Ref. ASM 38-14/01).
 B. Do the test as given in Para. 3.


 TOILET SYSTEM - FAULT ISOLATION PROCEDURES
__________________________________________
R **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
 TASK 38-31-00-810-803
 Vacuum Generator (37MG) Failure

 1. Possible Causes
_______________
 - GENERATOR-VACUUM (37MG)
 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 38-31-00-710-009 Operational Test of the Toilet Unit
 AMM 38-31-00-740-001 BITE Test of the Vacuum Toilet System
 AMM 38-31-64-000-001 Removal of the Vacuum Generator 37MG
 AMM 38-31-64-400-001 Installation of the Vacuum Generator 37MG

R **ON A/C 001-049, 051-099, 101-105, 151-158, 201-299,
 38-31-00-991-001 Fig. 201 R **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
 3. Fault Confirmation
__________________
 A. Fault Confirmation Test
 (1) Do the operational test of the toilet unit (Ref. AMM TASK 38-31-00-710-009).

 (2) Do the bite test of the vacuum toilet system (Ref. AMM TASK 38-31-00-740-001).

 

 4. Fault Isolation
_______________

 A. If the test gives a different maintenance message, you can find the related trouble shooting procedure in the applicable Page Block 101.
R **ON A/C 001-049, 051-099, 101-105, 151-158, 201-299,
 