R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
TASK 38-31-00-810-805
Liquid Level Sensor (41MG) Failure
1. Possible Causes
_______________
- SENSOR-LEVEL (41MG)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 38-31-00-710-009 Operational Test of the Toilet Unit
AMM 38-31-00-740-001 BITE Test of the Vacuum Toilet System
AMM 38-31-63-000-001 Removal of the Liquid Level Sensor (41MG)
AMM 38-31-63-400-001 Installation of the Liquid Level Sensor (41MG)
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
38-31-00-991-001 Fig. 201
**ON A/C 106-149, 301-399,
38-31-00-991-001-A Fig. 201A R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
3. Fault Confirmation
__________________
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
A. Do the operational test of the vacuum toilet system (Ref. AMM TASK 38-31-00-710-009).
B. Do the bite test (Ref. AMM TASK 38-31-00-740-001).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-149, 151-199, ∞∞38-31-00∞∞∞∞∞∞∞∞∞∞Page 208
201-299, 301-399, Aug 01/05 CES
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
4. Fault Isolation
_______________
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
A. If the operational test is OK:
- Refer to the trouble shooting page of the bite test. (Ref. Fig. 201/TASK 38-31-00-991-001)
(1) If the TROUBLE SHOOTING DATA page gives the maintenance message LIQD LVL SNSR:
- do a check of the electrical connections of the connector (41MG).
(2) If the electrical connections are OK:
- replace the SENSOR-LEVEL (41MG), (Ref. AMM TASK 38-31-63-000-001) and (Ref. AMM TASK 38-31-63-400-001).
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
B. If the test gives a different maintenance message, you can find the related trouble shooting procedure in the applicable Page Block 101.
- Refer to the CFDS-TROUBLE SHOOTING DATA page.
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
(Ref. Fig. 201/TASK 38-31-00-991-001)
**ON A/C 106-149, 301-399,
(Ref. Fig. 201A/TASK 38-31-00-991-001-A)
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
C. Test
(1) Do the operational test of the vacuum toilet system and make sure it operates correctly (Ref. AMM TASK 38-31-00-710-009).
(2) After the subsequent flight, make sure that the fault does not continue.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-149, 151-199, ∞∞38-31-00∞∞∞∞∞∞∞∞∞∞Page 209
201-299, 301-399, Aug 01/05 CES
MCDU Display
Figure 201A/TASK 38-31-00-991-001-A12 (SHEET 1)
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 106-149, 301-399, 401-499, ∞∞38-31-00∞∞∞∞∞∞∞∞∞∞Page 210
Aug 01/05 CES
MCDU Display
Figure 201A/TASK 38-31-00-991-001-A22 (SHEET 2)
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 106-149, 301-399, 401-499, ∞∞38-31-00∞∞∞∞∞∞∞∞∞∞Page 211
Aug 01/05 CESR **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
TASK 38-31-00-810-806
Vacuum System Controller (31MG) Failure
1. Possible Causes
_______________
- CONTROLLER-VACUUM SYSTEM (31MG)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
ASM 383100S11102 AMM 38-31-00-710-009 Operational Test of the Toilet Unit AMM 38-31-00-740-001 BITE Test of the Vacuum Toilet System AMM 38-31-34-000-001 Removal of the Vacuum System Controller 31MG AMM 38-31-34-400-001 Installation of the Vacuum System Controller 31MG 38-31-00-991-001 Fig. 201
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 WATER/WASTE(10)