WASTE WATER DRAIN - FAULT ISOLATION PROCEDURES
______________________________________________
TASK 38-32-00-810-801
Waste Water Drain - Failure
1. Possible Causes
_______________
- washbasin filter
- drain valve
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 38-32-00-100-001 Cleaning of the Waste Water Drain Lines
AMM 38-32-00-100-002 Cleaning of the Filter-Element of the Washbasin
Drain-Valve Assembly AMM 38-32-00-710-002 Operational Test of the Waste/Water Drain System AMM 38-32-41-000-001 Removal of the Drain Valve (Air Stop Valve) AMM 38-32-41-400-001 Installation of the Drain Valve (Air Stop Valve)
3. Fault Confirmation
__________________
A. Test
(1) Do a test of the waste water drain system (Ref. AMM TASK 38-32-00-710-002).
4. Fault Isolation
_______________
A. If the water drains too slow from the washbasin:
- Remove and clean the washbasin filter, (Ref. AMM TASK 38-32-00-100-002).
(1) If the fault continues:
- Replace the drain valve, (Ref. AMM TASK 38-32-41-000-001) and (Ref. AMM TASK 38-32-41-400-001).
(2) If the fault continues:
- Do the cleaning of the waste water lines (Ref. AMM TASK 38-32-00-100-001).
B. Do the test as given in paragraph 3. A. and check the correct operation of the waste water drain system.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 004-049, 053-099, 101-149, 151-199, ∞∞38-32-00∞∞∞∞∞∞∞∞∞∞Page 201
201-299, 301-399, 401-499, Aug 01/05 CES