 2. Job Set-up Information


______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 38-31-00-710-009 Operational Test of the Toilet Unit AMM 38-31-00-740-001 BITE Test of the Vacuum Toilet System
 3. Fault Confirmation
__________________
 A. Do a test of the vacuum toilet system (Ref. AMM TASK 38-31-00-710-009).
 B. Do the procedure to get access to the CFDS SYSTEM REPORT/TEST menu PAGE (Ref. AMM TASK 38-31-00-740-001).
 4. Fault Isolation
_______________
 A. Maintenance Action
 (1) Do the trouble shooting procedure related to the maintenance message as given in the TSM P.BLOCK 101.

 TASK 38-31-00-810-847


 Toilets Inop Due to Waste Tank Full
 1. Possible Causes

_______________

 2. Job Set-up Information


______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 12-16-38-613-001 Servicing of the Toilet System AMM 38-31-00-710-009 Operational Test of the Toilet Unit 38-31-00-991-001-A Fig. 201A
 3. Fault Confirmation
__________________
 A. Do a test of the vacuum toilet system (Ref. AMM TASK 38-31-00-710-009).
 4. Fault Isolation
_______________
 (Ref. Fig. 201A/TASK 38-31-00-991-001-A)

 A. If the FAP gives the maintenance message VACUUM SYSTEM DISABLE - WASTE TANK FULL:
 - do the servicing of the toilet system (Ref. AMM TASK 12-16-38-613-001).
 B. Test
 (1) Do the test as given in paragraph 3. A. to check the correct operation of the system.

 TASK 38-31-00-810-848


 Waste Tank not Empty (more than 30%)
 1. Possible Causes

_______________

 2. Job Set-up Information


______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 12-16-38-613-001 Servicing of the Toilet System AMM 38-31-00-710-009 Operational Test of the Toilet Unit
 3. Fault Confirmation
__________________
 A. Do a test of the vacuum toilet system (Ref. AMM TASK 38-31-00-710-009).
 4. Fault Isolation
_______________
 A. If the FAP gives the maintenance message WASTE TANK NOT EMPTY - CHECK LEVEL - GROUND SERVICE REQUIRED
 - do the servicing of the toilet system (Ref. AMM TASK 12-16-38-613-001).
 B. Test
 (1) Do the test as given in paragraph 3. A. to check the correct operation of the system.

 TASK 38-31-00-810-849


 Toilets Inop due to Servicing
 1. Possible Causes

_______________

 2. Job Set-up Information


______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 12-16-38-613-001 Servicing of the Toilet System AMM 38-31-00-710-009 Operational Test of the Toilet Unit
 3. Fault Confirmation
__________________
 A. Do a test of the vacuum toilet system (Ref. AMM TASK 38-31-00-710-009).
 4. Fault Isolation
_______________
 A. If the FAP gives the maintenance message VACUUM SYSTEM DISABLE - GROUND SERVICING
 - the toilets are not serviceable due to servicing (Ref. AMM TASK 12-16-38-613-001).
 B. Test
 (1) Do the test as given in paragraph 3. A. to check the correct operation of the system.

 **ON A/C ALL


 TASK 38-31-00-810-851
 Toilet System Shuts Down Constantly

 1. Possible Causes
_______________
 - vacuum leakage
 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 38-31-00-710-009 Operational Test of the Toilet Unit AMM 38-31-00-740-001 BITE Test of the Vacuum Toilet System R AMM 38-31-00-790-002 Leak Test of the Vacuum Toilet System
 3. Fault Confirmation
__________________
 A. Do a test of the vacuum toilet system (Ref. AMM TASK 38-31-00-710-009).
 