_ (Ref. AMM TASK 27-94-34-400-001).
(c) If the resistance is more than 250 ohms: 1 Do a check and repair the wiring of the ACS2 signal from the
_
SEC1 MON side to the first terminal block (Ref. ASM 27-94/02). 2 Install the SEC1 (Ref. AMM TASK 27-94-34-400-001).
_ R B. Do the test given in para. 3.
Loss of the ACS2 Signal of the SEC2 MON Side
1. Possible Causes
_______________
- SEC-2 (1CE2)
- wiring of the ACS2 signal from the SEC2 MON side to the first terminal block
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
27-90-00-810-801 Failure of an Alternating Current Supply (ACS)
AMM 27-94-34-000-001 Removal of the SEC (1CE1,1CE2,1CE3)
AMM 27-94-34-400-001 Installation of the SEC (1CE1,1CE2,1CE3)
R AMM 27-96-00-740-001 BITE Test of the EFCS (Ground Scanning) ASM 27-94/03
3. Fault Confirmation
__________________
A. Test Do the BITE Test of the EFCS (Ground Scanning) (Ref. AMM TASK 27-96-00-740-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance messages:
L SPLR5 POS XDCR 31CE9
and
R SPLR5 POS XDCR 31CE10
- remove the SEC2 (Ref. AMM TASK 27-94-34-000-001).
(1) At the SEC2 receptacle, do a check of the resistance and of the insulation between the pin AD/10H and the pin AD/10G (15 to 250 ohms) (Ref. ASM 27-94/03).
(a) If the resistance values are in the specified limits:
- replace the SEC-2 (1CE2) (Ref. AMM TASK 27-94-34-000-001) and (Ref. AMM TASK 27-94-34-400-001).
(b) If the resistance is less than 15 ohms:
1 Do the trouble shooting procedure (Ref. TASK 27-90-00-810-
_
801).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞27-90-00∞∞∞∞∞∞∞∞∞∞Page 208
Aug 01/99 CES 2 Replace the SEC-2 (1CE2) (Ref. AMM TASK 27-94-34-000-001) and
_ (Ref. AMM TASK 27-94-34-400-001).
(c) If the resistance is more than 250 ohms: 1 Do a check and repair the wiring of the ACS2 signal from the
_
SEC2 MON side to the first terminal block (Ref. ASM 27-94/03). 2 Install the SEC2 (Ref. AMM TASK 27-94-34-400-001).
_ R B. Do the test given in para. 3.
Loss of the ACS2 Signal of the SEC3 COM side
1. Possible Causes
_______________
- SEC-3 (1CE3)
- wiring of the ACS2 signal from the SEC3 COM side to the first terminal block
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
27-90-00-810-801 Failure of an Alternating Current Supply (ACS)
AMM 27-94-34-000-001 Removal of the SEC (1CE1,1CE2,1CE3)
AMM 27-94-34-400-001 Installation of the SEC (1CE1,1CE2,1CE3)
R AMM 27-96-00-740-001 BITE Test of the EFCS (Ground Scanning) ASM 27-94/04
3. Fault Confirmation
__________________
A. Test Do the BITE Test of the EFCS (Ground Scanning) (Ref. AMM TASK 27-96-00-740-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance messages:
L SPLR1 POS XDCR 31CE1
and
R SPLR1 POS XDCR 31CE2
- remove the SEC3 (Ref. AMM TASK 27-94-34-000-001).
(1) At the SEC3 receptacle, do a check of the resistance and of the insulation between the pin AA/14F and the pin AA/14G (15 to 250 ohms) (Ref. ASM 27-94/04).
(a) If the resistance values are in the specified limits:
- replace the SEC-3 (1CE3) (Ref. AMM TASK 27-94-34-000-001) and (Ref. AMM TASK 27-94-34-400-001).
(b) If the resistance is less than 15 ohms:
1 Do the trouble shooting procedure (Ref. TASK 27-90-00-810-
_
801).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞27-90-00∞∞∞∞∞∞∞∞∞∞Page 210
Aug 01/99 CES 2 Replace the SEC-3 (1CE3) (Ref. AMM TASK 27-94-34-000-001) and
_ (Ref. AMM TASK 27-94-34-400-001).
(c) If the resistance is more than 250 ohms: 1 Do a check and repair the wiring of the ACS2 signal from the