1. Possible Causes
_______________
- ELAC-2 (2CE2)
- SEC-2 (1CE2)
- wiring of the ACS1 SPLY signal from the ELAC2 MON side to the COM side
- wiring of the ACS1 SPLY MON signal from the ELAC2 COM side to the first terminal block
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION
-------------------------------------------------------------------------------
27-90-00-810-801 Failure of an Alternating Current Supply (ACS)
AMM 27-93-34-000-001 Removal of the ELAC (2CE1,2CE2)
AMM 27-93-34-400-001 Installation of the ELAC (2CE1,2CE2)
AMM 27-94-34-000-001 Removal of the SEC (1CE1,1CE2,1CE3)
AMM 27-94-34-400-001 Installation of the SEC (1CE1,1CE2,1CE3)
AMM 27-96-00-740-001 BITE Test of the EFCS (Ground Scanning)
ASM 27-93/08
3. Fault Confirmation
__________________
A. Test
(1) Do the BITE test of the EFCS (ground scanning) (Ref. AMM TASK 27-96-00-740-001).
4. Fault Isolation
_______________
A. If the ground scanning gives at least two maintenance messages of the list below: ELAC2 MON OR INPUT OF THS ACTR XDCR1 9CE ELAC2 OR WIRING FROM L ELEV POS MON XDCR ELAC2 OR WIRING FROM R ELEV POS MON XDCR ELAC2 OR WIRING FROM L B ELEV MODE XDCR 34CE3 ELAC2 OR WIRING FROM R Y ELEV MODE XDCR 34CE4
(1) Remove the ELAC2 (Ref. AMM TASK 27-93-34-000-001) and the SEC2 (Ref. AMM TASK 27-94-34-000-001).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞27-90-00∞∞∞∞∞∞∞∞∞∞Page 232
May 01/04R
CES
(2) At the ELAC2 receptacle, do a check of the resistance between the pin AB/7K and the pin AB/8K (Ref. ASM 27-93/08):
(a) If the resistance is less than 10 Ohms:
1 Do this procedure (Ref. TASK 27-90-00-810-801).
_
2 Replace the ELAC-2 (2CE2) (Ref. AMM TASK 27-93-34-000-001) and
_ (Ref. AMM TASK 27-93-34-400-001).
3 Replace the SEC-2 (1CE2) (Ref. AMM TASK 27-94-34-000-001) and
_ (Ref. AMM TASK 27-94-34-400-001).
(b) If the resistance value is more than 10 Ohms:
- do a check of the wiring of the ACS1 SPLY signal from the ELAC2 MON side to the COM side (Ref. ASM 27-93/08): . pins AE/1J and AE/1K to pins AE/11B and AE/10B of the ELAC2 MON side . pins AE/10A and AE/11A of the ELAC2 MON side to pins AB/8J and AB/7J of the ELAC2 COM side.
1 If the wiring is not correct:
_
- repair it
- install the ELAC2 (Ref. AMM TASK 27-93-34-400-001) and the SEC2 (Ref. AMM TASK 27-94-34-400-001).
a If the fault continues:
_
- replace the ELAC-2 (2CE2) (Ref. AMM TASK 27-93-34-000-001) and (Ref. AMM TASK 27-93-34-400-001).
2 If the wiring is correct:
_ a Replace the ELAC-2 (2CE2) (Ref. AMM TASK 27-93-34-000-001)
_ and (Ref. AMM TASK 27-93-34-400-001).
b Install the SEC2 (Ref. AMM TASK 27-94-34-400-001).
_
c If the fault continues:
_
- do a check and repair the wiring of the ACS1 SPLY MON signal from the ELAC2 COM side to the first terminal block, pins AB/7K and AB/8K (Ref. ASM 27-93/08).
B. Do the test given in para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞27-90-00∞∞∞∞∞∞∞∞∞∞Page 233
May 01/04R CES
Loss of the ACS1 of the ELAC2 COM and MON Sides
1. Possible Causes
_______________
- ELAC-2 (2CE2)
- SEC-1 (1CE1)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
27-90-00-810-814 Loss of the ACS1 Signal of the ELAC2 COM Side
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 飞行操纵 2(102)