3. Fault Confirmation
__________________
A. Test
(1) Do the BITE test of the EFCS (ground scanning) (Ref. AMM TASK 27-96-00-740-001).
4. Fault Isolation
_______________
A. If the ground scanning gives at least two maintenance messages of the list below: L B ELEV POS XDCR 34CE3 COM E1/S1 : USE STBY XDCR R B ELEV POS XDCR 34CE4 COM E1/S1 : USE STBY XDCR THS ACTR XDCR2 9CE
(1) Remove the ELAC1 (Ref. AMM TASK 27-93-34-000-001) and the SEC1 (Ref. AMM TASK 27-94-34-000-001).
(2) At the SEC1 receptacle, do a check of the resistance between the pin AA/12F and the pin AA/12G (Ref. ASM 27-94/07):
(a) If the resistance is less than 10 Ohms:
1 Do this procedure (Ref. TASK 27-90-00-810-801).
_
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞27-90-00∞∞∞∞∞∞∞∞∞∞Page 240
May 01/04R CES
2_ Replace the ELAC-1 (2CE1) (Ref. AMM TASK 27-93-34-000-001) and
(Ref. AMM TASK 27-93-34-400-001).
3_ Replace the SEC-1 (1CE1) (Ref. AMM TASK 27-94-34-000-001) and
(Ref. AMM TASK 27-94-34-400-001).
(b) If the resistance is more than 10 Ohms: 1 Replace the SEC-1 (1CE1) (Ref. AMM TASK 27-94-34-000-001) and
_ (Ref. AMM TASK 27-94-34-400-001). Install the ELAC1 (Ref. AMM TASK 27-93-34-400-001).
2 If the fault continues:
_
- replace the ELAC-1 (2CE1) (Ref. AMM TASK 27-93-34-000-001) and (Ref. AMM TASK 27-93-34-400-001).
3 If the fault continues:
_
- do a check and repair the wiring of the ACS1 SPLY XDCR signal from the SEC1 COM side to the second terminal block, pins AA/12F and AA/12G (Ref. ASM 27-94/07).
B. Do the test given in para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞27-90-00∞∞∞∞∞∞∞∞∞∞Page 241
May 01/04R
CES Loss of the ACS1 Signal of the ELAC1 MON Side and SEC1 MON Side
1. Possible Causes
_______________
- ELAC-1 (2CE1)
- SEC-1 (1CE1)
- wiring of the ACS1 SPLY XDCR signal from the SEC1 MON side to the COM side
- wiring of the ACS1 SPLY XDCR COM signal from the SEC1 MON side to the second terminal block
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION
-------------------------------------------------------------------------------
27-90-00-810-801 Failure of an Alternating Current Supply (ACS)
AMM 27-93-34-000-001 Removal of the ELAC (2CE1,2CE2)
AMM 27-93-34-400-001 Installation of the ELAC (2CE1,2CE2)
AMM 27-94-34-000-001 Removal of the SEC (1CE1,1CE2,1CE3)
AMM 27-94-34-400-001 Installation of the SEC (1CE1,1CE2,1CE3)
AMM 27-96-00-740-001 BITE Test of the EFCS (Ground Scanning)
ASM 27-94/07
3. Fault Confirmation
__________________
A. Test
(1) Do the BITE test of the EFCS (ground scanning) (Ref. AMM TASK 27-96-00-740-001).
4. Fault Isolation
_______________
A. If the ground scanning gives at least two maintenance messages of the list below: L ELEV POS MON XDCR OF ELAC1/SEC1 L G ELEV MODE XDCR 34CE1 R B ELEV POS MON XDCR OF ELAC1/SEC1 R Y ELEV MODE XDCR 34CE2 THS ACTR XDCR2 MON 9CE
(1) Remove the ELAC1 (Ref. AMM TASK 27-93-34-000-001) and the SEC1 (Ref. AMM TASK 27-94-34-000-001).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞27-90-00∞∞∞∞∞∞∞∞∞∞Page 242
May 01/04R
CES
(2) At the SEC1 receptacle, do a check of the resistance between the pin AB/9E and the pin AB/9F (Ref. ASM 27-94/07):
(a) If the resistance is less than 10 Ohms:
1 Do this procedure (Ref. TASK 27-90-00-810-801).
_ 2 Replace the ELAC-1 (2CE1) (Ref. AMM TASK 27-93-34-000-001) and
_
(Ref. AMM TASK 27-93-34-400-001).