4. Fault Isolation
_______________
R R A. If the BITE test gives the maintenance message: Y HYD PRESS SW1 - replace the PRESS SW-Y HYD, FLT CTL (10CE3), (Ref. AMM TASK 27-92-17-000-002) and (Ref. AMM TASK 27-92-17-400-002). - open and close the circuit breakers 20CE1 and 20CE2.
R (1) If the fault continues: - do a check and repair the wiring from the pressure switch (10CE3) pin A/B to the first terminal block, (Ref. ASM 27-92/27). - open and close the circuit breakers 20CE1 and 20CE2.
B. Do the BITE test given in Para. 3.
5. Close-up________
A. Depressurize the Yellow hydraulic system (Ref. AMM TASK 29-10-00-864-002).
Failure of the Yellow Hydraulic Pressure Switch (3151GN)
1. Possible Causes
_______________
- PRESS SW-FLT CTL, Y (3151GN)
- wiring from the pressure switch (3151GN) pin A/B to the first terminal block
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
31-32-00-810-932 Failure of the Discrete Links
R AMM 27-96-00-740-001 BITE Test of the EFCS (Ground Scanning) AMM 29-10-00-863-002 Pressurize the Yellow Hydraulic System AMM 29-10-00-864-002 Depressurize the Yellow Hydraulic System AMM 29-32-12-000-003 Removal of the System Pressure Switch (3151GN) AMM 29-32-12-400-003 Installation of the System Pressure Switch (3151GN) ASM 27-92/27
3. Fault Confirmation
__________________
A. Job Set-Up
(1) Pressurize the Yellow hydraulic system (Ref. AMM TASK 29-10-00-863-002).
B. Table of the circuit breakers used in this procedure:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU FLIGHT CONTROLS/FCDC1/SPLY 20CE1 B10 121VU FLIGHT CONTROLS/FCDC2/SPLY 20CE2 Q20
C. Test
(1) Do the BITE test of the EFCS (Ground Scanning) (Ref. AMM TASK 27-96-00-740-001).
4. Fault Isolation
_______________
A. If the BITE test gives the maintenance message:
Y HYD PRESS SW2
- do the trouble shooting procedure (Ref. TASK 31-32-00-810-932) . related to the DSI 19 discret input signal of the SEC 2 and SEC 3, . related to the DSI 32 discret input signal of the ELAC 1 MON and ELAC 2 MON (Ref. ASM 27-92/27)
- open and close the circuit breakers 20CE1 and 20CE2.
(1) If the fault continues:
- replace the PRESS SW-FLT CTL, Y (3151GN), (Ref. AMM TASK 29-32-12-
000-003) and (Ref. AMM TASK 29-32-12-400-003). - open and close the circuit breakers 20CE1 and 20CE2.
(a) If the fault continues:
- do a check and repair the wiring from the pressure switch (3151GN) pin A/B to the first terminal block, (Ref. ASM 27-92/27).
- open and close the circuit breakers 20CE1 and 20CE2.
B. Do the BITE test given in Para. 3.
5. Close-up
________
A. Depressurize the Yellow hydraulic system (Ref. AMM TASK 29-10-00-864-002).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞27-92-00∞∞∞∞∞∞∞∞∞∞Page 222
Feb 01/99R
CES Failure of the Yellow Hydraulic Pressure Transducer
1. Possible Causes
_______________
- PRESS XDCR-Y (3065GN)
- wiring of the 28VDC signal from the pressure transducer (3065GN) to the first terminal block 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320 Trouble Shooting Manual 排故手册 飞行操纵 2(115)