1. Possible Causes
_______________
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
27-30-00-810-848 Elevator Damping Test not Possible
AMM 27-96-00-710-008 Operational Test of the Damping Measurement
(Elevator)
27-30-00-991-002 Fig. 202
27-30-00-991-003 Fig. 203
3. Fault Confirmation
__________________
A. Test
(1) Do the operational test of the damping measurement (elevator) (Ref. AMM TASK 27-96-00-710-008). (Ref. Fig. 202/TASK 27-30-00-991-002)
4. Fault Isolation
_______________
A. If the message ELEV TEST NOT POSSIBLE is shown on the MCDU associated to:
(1) Code of normal engagement conditions (code: 03FF):
- do the trouble shooting procedure (Ref. TASK 27-30-00-810-848).
(2) Another code (different of 03FF):
- do the decoding procedure
(Ref. Fig. 203/TASK 27-30-00-991-003)
R B. Do the test given in para. 3.
R MCDU Procedure of the Elevator Damping Test Figure 202/TASK 27-30-00-991-002
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞27-30-00∞∞∞∞∞∞∞∞∞∞Page 297
May 01/04 CES
R Decoding Table of the Elevator Damping Test Not Possible Figure 203/TASK 27-30-00-991-003
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞27-30-00∞∞∞∞∞∞∞∞∞∞Page 298
May 01/04 CES Operational Test of the Damping Measurement (Elevator) not OK
1. Possible Causes
_______________
- elevator servocontrol
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
R AMM 27-34-51-000-001 Removal of the Elevator Servo Control R AMM 27-34-51-400-001 Installation of the Elevator Servo Control AMM 27-96-00-710-008 Operational Test of the Damping Measurement (Elevator)
3. Fault Confirmation
__________________
A. Test Do the operational test of the damping measurement (elevator) (Ref. AMM TASK 27-96-00-710-008).
4. Fault Isolation
_______________
A. If the damping factor in the down or in the up position is less than 0,25:
- replace the related elevator servocontrol (34CE1 or 34CE2 or 34CE3 or 34CE4) (Ref. AMM TASK 27-34-51-000-001) and (Ref. AMM TASK 27-34-51-400-001) .
B. Do the test given in Para. 3.