- if the result of the test is in the tolerances, see Para. (b).
(a) Replace the SERVO CTL-R ELEVATOR, INBD Y (34CE2) and the SERVO CTL-R ELEVATOR, OUTBD B (34CE4) of the right elevator (Ref. AMM TASK 27-34-51-000-001) and (Ref. AMM TASK 27-34-51-400-001).
NOTE : The resistance of primary and secondary windings must be
____ between 30 ohms and 500 ohms.
(b) Do the operational test of the elevator and hydraulic actuation (Ref. AMM TASK 27-34-00-710-001).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞27-30-00∞∞∞∞∞∞∞∞∞∞Page 250
Aug 01/03 CES Loss of the Signal of the Right Elevator Position Transducer (MON) by the SEC 1
1. Possible Causes
_______________
- SEC-1 (1CE1)
- wiring of the POS XDCR MON (ANI 2-2) signal from the SEC 1 (1CE1) MON part to the first terminal block
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
27-90-00-810-818 Loss of the ACS1 Signal of the SEC1 MON Side
AMM 27-94-34-000-001 Removal of the SEC (1CE1,1CE2,1CE3)
AMM 27-94-34-400-001 Installation of the SEC (1CE1,1CE2,1CE3)
AMM 27-96-00-710-020 Operational Test of the Side Stick Assembly
(Activation for the BITE Test)
AMM 27-96-00-740-001 BITE Test of the EFCS (Ground Scanning)
ASM 27-94/07
3. Fault Confirmation
__________________
A. Test
(1) Do the operational test of the side stick assembly (Activation for the BITE test) (Ref. AMM TASK 27-96-00-710-020).
NOTE : Before you start the operational test procedure, release the
____ FLT CTL/ELAC 1, FLT CTL/ELAC 2 and FLT CTL/SEC 2 pushbutton switches (on these pushbutton switches the OFF legends come on).
(2) Do the BITE test of the EFCS (ground scanning) (Ref. AMM TASK 27-96-00-740-001).
(a) If the ground scanning gives the maintenance message: SEC1 OR WIRING FROM R ELEV POS MON XDCR
- refer to Para. Fault Isolation.
(b) If the ground scanning gives at least two maintenance messages of the list below: SEC1 OR WIRING FROM L ELEV POS MON XDCR SEC1 OR WIRING FROM R ELEV POS MON XDCR SEC1 MON OR WIRING FROM THS ACTR XDCR2 9CE SEC1 OR WIRING FROM L G ELEV MODE XDCR 34CE1 SEC1 OR WIRING FROM R Y ELEV MODE XDCR 34CE2
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞27-30-00∞∞∞∞∞∞∞∞∞∞Page 251
Aug 01/00R CES
- do this trouble shooting procedure (Ref. TASK 27-90-00-810-818).
4. Fault Isolation
_______________
A. If the test gives the maintenance message:
SEC1 OR WIRING FROM R ELEV POS MON XDCR
- replace the SEC-1 (1CE1) (Ref. AMM TASK 27-94-34-000-001) and (Ref. AMM TASK 27-94-34-400-001).
(1) If the fault continues:
- do a check and repair the wiring of the POS XDCR MON (ANI 2-2) signal from the SEC 1 (1CE1) MON part to the first terminal block (Ref. ASM 27-94/07).
B. Do the tests given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞27-30-00∞∞∞∞∞∞∞∞∞∞Page 252
Aug 01/00R
CES Failure of the Right Blue Elevator-Servocontrol Servovalve
1. Possible Causes
_______________
- servovalve of the servocontrol 34CE4
- wiring of the SV signal from the servocontrol (34CE4) to the first terminal block
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 27-34-51-000-008 Removal of the Elevator Servo Control Actuator Servo Valve AMM 27-34-51-400-003 Installation of the Elevator Servo Control Actuator Servo Valve AMM 27-96-00-710-020 Operational Test of the Side Stick Assembly
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 飞行操纵 1(55)