 - wiring of the MODE XDCR V1 signal from the servocontrol (34CE3) to the first terminal block


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
27-90-00-810-824 Loss of the ACS1 Signal of the ELAC2 MON Side and
 SEC2 MON Side 31-32-00-810-933 Failure of the Analog Links AMM 27-34-51-000-006 Removal of the Elevator Servo Control Actuator Mode
 Selector Valve Transducer MSVT AMM 27-34-51-400-005 Installation of the Elevator Servo Control Actuator Mode Selector Valve Transducer MSVT AMM 27-96-00-710-020 Operational Test of the Side Stick Assembly
 (Activation for the BITE Test)
 AMM 27-96-00-740-001 BITE Test of the EFCS (Ground Scanning)
 ASM 27-93/08
 ASM 27-94/08

 3. Fault Confirmation
__________________
 A. Test
 (1) Do the operational test of the side stick assembly (Activation for the BITE Test) (Ref. AMM TASK 27-96-00-710-020).

 (2) Do the BITE test of the EFCS (ground scanning) (Ref. AMM TASK 27-96-00-740-001).

 (a) If the ground scanning gives the maintenance message: L B ELEV MODE XDCR 34CE3

 - refer to Para. Fault Isolation.

 (b) If the ground scanning gives at least two maintenance messages of the list below: L B ELEV MODE XDCR 34CE3 L ELEV POS MON XDCR OF ELAC2/SEC2 R B ELEV MODE XDCR 34CE4

 


 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞27-30-00∞∞∞∞∞∞∞∞∞∞Page 215
 Feb 01/04R CES

 

 R Y ELEV POS MON XDCR OF ELAC2/SEC2 ELAC2 MON OR INPUT OF THS ACTR XDCR1 9CE SEC2 MON OR INPUT OF THS ACTR XDCR3 9CE
 - do this trouble shooting procedure (Ref. TASK 27-90-00-810-824).
 4. Fault Isolation
_______________
 A. If the test gives the maintenance message:
 L B ELEV MODE XDCR 34CE3

 - do the trouble shooting procedure (Ref. TASK 31-32-00-810-933) related R to the ANI 7-X analog input signal of the ELAC MON and SEC MON (Ref. R ASM 27-93/08) and (Ref. ASM 27-94/08).
 (1) If the fault continues:
 - replace the mode selector valve transducer of the servocontrol (34CE3) (Ref. AMM TASK 27-34-51-000-006) and (Ref. AMM TASK 27-34-51-400-005).
 NOTE : The resistance of primary and secondary windings must be
____
 between 30 ohms and 500 ohms.

 (2) If the fault continues:
 (a) Do a check of the wiring of the MODE XDCR SPLY signal from the servocontrol (34CE3) to the first terminal block (Ref. ASM 27-93/08):

 - if there is continuity, see Para. (b)

 - if there is no continuity, repair the above wiring.

 

 (b) Repair the wiring of the MODE XDCR V1 signal from the servocontrol (34CE3) to the first terminal block (Ref. ASM 27-93/08).


 B. Do the tests given in Para. 3.

 


 Loss of the Left Blue Elevator-Servocontrol Mode-Transducer by the SEC 2
 1. Possible Causes
_______________
 - SEC-2 (1CE2)

 - wiring of the L B SERVO CTL MODE POS (ANI 7-1) from the SEC 2 (1CE2) MON part to the first terminal block


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
27-90-00-810-822 Loss of the ACS1 Signal of the SEC2 MON Side
 AMM 27-94-34-000-001 Removal of the SEC (1CE1,1CE2,1CE3)
 AMM 27-94-34-400-001 Installation of the SEC (1CE1,1CE2,1CE3)
 AMM 27-96-00-710-020 Operational Test of the Side Stick Assembly

 (Activation for the BITE Test) R AMM 27-96-00-740-001 BITE Test of the EFCS (Ground Scanning) ASM 27-94/08
 3. Fault Confirmation
__________________
 A. Test
 (1) Do the operational test of the side stick assembly (Activation for the BITE Test) (Ref. AMM TASK 27-96-00-710-020).
 NOTE : Before you start the operational test procedure, release the
____ FLT CTL/ELAC 1 and FLT CTL/ELAC 2 pushbutton switches (on these pushbutton switches the OFF legends come on).
 (2) Do the BITE test of the EFCS (ground scanning) (Ref. AMM TASK 27-96-00-740-001).
 (a) If the ground scanning gives the maintenance message: SEC2 OR WIRING FROM L B ELEV MODE XDCR 34CE3

 - refer to Para. Fault Isolation.

 (b) If the ground scanning gives at least two maintenance messages of the list below: SEC2 OR WIRING FROM L B ELEV MODE XDCR 34CE3 SEC2 OR WIRING FROM L ELEV POS MON XDCR SEC2 OR WIRING FROM R B ELEV MODE XDCR 34CE4 SEC2 OR WIRING FROM R ELEV POS MON XDCR SEC2 MON OR INPUT OF THS ACTR XDCR3 9CE
 
中国航空网 www.aero.cn