 Nov 01/04 CES

 

 ELEVATOR - FAULT ISOLATION PROCEDURES
_____________________________________
 TASK 27-30-00-810-801
 Failure of the Left Blue Elevator-Servocontrol Position-Transducer
 1. Possible Causes
_______________
 - SERVO CTL-L ELEVATOR, OUTBD B (34CE3)

 - wiring of the POS XDCR COM SPLY signal from the servocontrol (34CE3) to the first terminal block

 - wiring of the POS XDCR COM V1, V2 signals from the servocontrol (34CE3) to the first terminal block


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
27-90-00-810-819 Loss of the ACS1 Signal of the ELAC1 COM Side and
 SEC1 COM Side
 31-32-00-810-933 Failure of the Analog Links
 AMM 27-34-00-040-001 Elevator Servocontrol Position-Transducer -
Connection of the Spare Transducer
 AMM 27-34-00-440-001 Reactivation of Elevator Servocontrol

 Position-Transducer R AMM 27-34-51-000-001 Removal of the Elevator Servo Control R AMM 27-34-51-400-001 Installation of the Elevator Servo Control
 AMM 27-96-00-710-020 Operational Test of the Side Stick Assembly
 (Activation for the BITE Test)
 AMM 27-96-00-740-001 BITE Test of the EFCS (Ground Scanning)
 ASM 27-93/07
 ASM 27-94/07

 3. Fault Confirmation
__________________
 A. Test
 (1) Do the operational test of the side stick assembly (Activation for the BITE test) (Ref. AMM TASK 27-96-00-710-020).

 (2) Do the BITE test of the EFCS (ground scanning) (Ref. AMM TASK 27-96-00-740-001).


 (a) If the ground scanning gives the maintenance message: L B ELEV POS XDCR 34CE3 COM E1/S1 : USE STBY XDCR
 - refer to Para. Fault Isolation.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞27-30-00∞∞∞∞∞∞∞∞∞∞Page 201
 Aug 01/03 CES

 

 (b) If the ground scanning gives at least two maintenance messages of the list below: L B ELEV POS XDCR 34CE3 COM E1/S1 : USE STBY XDCR R B ELEV POS XDCR 34CE4 COM E1/S1 : USE STBY XDCR THS ACTR XDCR2 9CE
R - do this trouble shooting procedure (Ref. TASK 27-90-00-810-R 819).
 4. Fault Isolation
_______________
 A. If the test gives the maintenance message:
 L B ELEV POS XDCR 34CE3 COM E1/S1 : USE STBY XDCR

 - deactivate the defective RVDT and connect the spare RVDT (Ref. AMM TASK 27-34-00-040-001) and (Ref. AMM TASK 27-34-00-440-001).
 (1) If the fault continues:

 - do the trouble shooting procedure (Ref. TASK 31-32-00-810-933) related to the ANI 2-X analog input signal of the ELAC COM and SEC COM (Ref. ASM 27-93/07) and (Ref. ASM 27-94/07).

 (2) If the fault continues:


 - replace the SERVO CTL-L ELEVATOR, OUTBD B (34CE3) (Ref. AMM TASK 27-34-51-000-001) and (Ref. AMM TASK 27-34-51-400-001).
 NOTE : The resistance of primary and secondary windings must be
____
 between 30 ohms and 500 ohms.

 (3) If the fault continues:
 (a) Do a check of the wiring of the POS XDCR COM SPLY signal from the servocontrol (34CE3) to the first terminal block (Ref. ASM 27-93/07):

 - if there is continuity, see Para. (b)

 - if there is no continuity, repair the above wiring.

 

 (b) Do a check and repair the wiring of the POS XDCR COM V1, V2 signals from the servocontrol (34CE3) to the first terminal block (Ref. ASM 27-93/07).


 B. Do the tests given in Para. 3.

 


 Loss of the Signal of the Left Blue Elevator-Servocontrol Position-Transducer
 by the SEC 1
 1. Possible Causes
_______________
 - SEC-1 (1CE1)

 - wiring of the POS XDCR COM (ANI 2-1) signal from the SEC 1 (1CE1) to the first terminal block


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
27-90-00-810-817 Loss of the ACS1 Signal of the SEC1 COM Side
 AMM 27-94-34-000-001 Removal of the SEC (1CE1,1CE2,1CE3)
 AMM 27-94-34-400-001 Installation of the SEC (1CE1,1CE2,1CE3)
 AMM 27-96-00-710-020 Operational Test of the Side Stick Assembly

 (Activation for the BITE Test) R AMM 27-96-00-740-001 BITE Test of the EFCS (Ground Scanning) ASM 27-94/07
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 飞行操纵 1(37)