 AMM 27-34-51-400-004 Installation of the Elevator Servo Control Actuator
R Solenoid Valve AMM 27-94-34-000-001 Removal of the SEC (1CE1,1CE2,1CE3) AMM 27-94-34-400-001 Installation of the SEC (1CE1,1CE2,1CE3) AMM 27-96-00-710-020 Operational Test of the Side Stick Assembly
 (Activation for the BITE Test)
 AMM 27-96-00-740-001 BITE Test of the EFCS (Ground Scanning)
 ASM 27-94/07

 3. Fault Confirmation
__________________
 A. Test
 (1) Do the operational test of the side stick assembly (Activation for the BITE test) (Ref. AMM TASK 27-96-00-710-020).

 NOTE : Before you start the operational test procedure, release the
____ FLT CTL/ELAC 1, FLT CTL/ELAC 2 and FLT CTL/SEC 2 pushbutton switches (on these pushbutton switches the OFF legends come on).
 (2) Do the BITE test of the EFCS (ground scanning) (Ref. AMM TASK 27-96-00-740-001).
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞27-30-00∞∞∞∞∞∞∞∞∞∞Page 283
 Aug 01/03 CES


 4. Fault Isolation
_______________


 A. If the test gives the maintenance message:
 SEC1 MON OR WIRING TO R Y ELEV SOL VLV 34CE2

 (1) Remove the SEC1 (Ref. AMM TASK 27-94-34-000-001).

 (2) At the SEC1 receptacle, do a check of the resistance between the pin AB/15D and the pin AE/15G (Ref. ASM 27-94/07).


 NOTE : The resistance must be between 40 and 100 Ohms.
____

 (a) If the resistance is less than 40 Ohms:
 - at the inboard elevator servocontrol (34CE2), do a check of the resistance of the solenoid valve between the pin C/J and the pin C/U (Ref. ASM 27-94/07).
 NOTE : The resistance must be between 40 and 100 Ohms.
____

 1 If the resistance values are out of the specified limits:
_ a Replace the solenoid valve of the servocontrol 34CE2 (Ref.

_ AMM TASK 27-34-51-000-005) and (Ref. AMM TASK 27-34-51-400-004).
 b Do again a check of the resistance of the solenoid valve
_ between the pin C/J and the pin C/U of the inboard elevator servocontrol (34CE2) (40 to 100 Ohms).
 - If the resistance values are out of the specified limits: . Replace the SERVO CTL-R ELEVATOR, INBD Y (34CE2) (Ref. AMM TASK 27-34-51-000-001) and (Ref. AMM TASK 27-34-51-400-001). . Replace the SEC-1 (1CE1) (Ref. AMM TASK 27-94-34-000-001) and (Ref. AMM TASK 27-94-34-400-001).

 - If the resistance values are in the specified limits: Replace the SEC-1 (1CE1) (Ref. AMM TASK 27-94-34-000-001) and (Ref. AMM TASK 27-94-34-400-001).


 2 If the resistance values are in the specified limits:
_ a Repair the wiring of the SOL VLV2 signal from the

_ servocontrol (34CE2) to the SEC1 (1CE1), from the pin C/J to the pin AB/15D and from the pin C/U to the pin AE/15G (Ref. ASM 27-94/07):
 b Replace the SEC-1 (1CE1) (Ref. AMM TASK 27-94-34-000-001)
_ and (Ref. AMM TASK 27-94-34-400-001).
 (b) If the resistance is more than 100 Ohms:
 - at the inboard elevator servocontrol (34CE2), do a check of the resistance of the solenoid valve between the pin C/J and the pin C/U (Ref. ASM 27-94/07).
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞27-30-00∞∞∞∞∞∞∞∞∞∞Page 284
 Aug 01/00R CES

 

____

 1 If the resistance values are out of the specified limits:
_ a Replace the solenoid valve of the servocontrol 34CE2 (Ref.

_ AMM TASK 27-34-51-000-005) and (Ref. AMM TASK 27-34-51-400-004).
 b Do again a check of the resistance of the solenoid valve
_ between the pin C/J and the pin C/U of the inboard elevator servocontrol (34CE2) (40 to 100 Ohms).
 - If the resistance values are out of the specified limits: . Replace the SERVO CTL-R ELEVATOR, INBD Y (34CE2) (Ref. AMM TASK 27-34-51-000-001) and (Ref. AMM TASK 27-34-51-400-001). . Install the SEC1 (Ref. AMM TASK 27-94-34-400-001).

 - If the resistance values are in the specified limits: Install the SEC1 (Ref. AMM TASK 27-94-34-400-001).


 2 If the resistance values are in the specified limits:
_ a Repair the wiring of the SOL VLV2 signal from the

_ servocontrol (34CE2) to the SEC1 (1CE1), from the pin C/J to the pin AB/15D and from the pin C/U to the pin AE/15G (Ref. ASM 27-94/07):
 b Install the SEC1 (Ref. AMM TASK 27-94-34-400-001).
_

 (c) If the resistance values are in the specified limits: R - See Para. (3).
R (3) At the SEC1 receptacle, do a check of the insulation between pin R AE/15G (pin AB/15D) and the ground.
R NOTE : The resistance must be more than 100 Meghoms.
 