Unexpected Lavatory Smoke-Detector
1. Possible Causes
_______________
- MODULE-CABIN ASSIGNMENT (115RH)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 23-73-00-740-010 Interface and Power-Up Test of the Cabin
Intercommunication Data System (CIDS) via the CFDS AMM 23-73-19-000-002 Removal of the Cabin Assignment Module (115RH) AMM 23-73-19-400-002 Installation of the Cabin Assignment Module (115RH)
3. Fault Confirmation
__________________
A. Test
(1) Do the CIDS Interface and Power-Up Test via the CFDS (Ref. AMM TASK 23-73-00-740-010).
4. Fault Isolation
_______________
A. If the test gives a different maintenance message:
- Do the trouble shooting procedure related to the maintenance message.
B. If the test confirms the fault:
- make sure that the cabin assignment module (CAM) is applicable to the cabin layout (number and location of the lavatories),
- replace the MODULE-CABIN ASSIGNMENT (115RH) (Ref. AMM TASK 23-73-19-000-002) and (Ref. AMM TASK 23-73-19-400-002).
C. Do the test as given in the Para. 3.
5. Close-up
________
A. Put the aircraft back to its initial configuration.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 106-149, 301-399, 401-499, ∞∞26-17-00∞∞∞∞∞∞∞∞∞∞Page 234
Aug 01/05 CES Communication RS232 to CIDS Main-Board failed
1. Possible Causes
_______________
- CIDS Director
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 23-73-00-740-010 Interface and Power-Up Test of the Cabin
Intercommunication Data System (CIDS) via the CFDS AMM 23-73-34-000-001 Removal of the CIDS Director (101RH,102RH) AMM 23-73-34-400-001 Installation of the CIDS Director (101RH,102RH)
3. Fault Confirmation
__________________
A. Test
(1) Do the CIDS Interface and Power-Up Test via the CFDS (Ref. AMM TASK 23-73-00-740-010)
4. Fault Isolation
_______________
A. If the test gives a different maintenance message:
- Do the trouble shooting procedure related to the maintenance message.
B. If the test gives the maintenance message DIRY(10YRH)-SDF:
- replace the related CIDS Director (10YRH) (Ref. AMM TASK 23-73-34-000-001) and (Ref. AMM TASK 23-73-34-400-001)
C. Do the test given in para. 3.
5. Close-up
________
A. Put the aircraft back to its initial configuration.
CIDS-SDF Channel 1 and 2 Failure
1. Possible Causes
_______________
- DIR-CIDS, 2 (102RH)
- DIR-CIDS, 1 (101RH)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
R AMM 23-73-34-000-001 Removal of the CIDS Director (101RH,102RH) AMM 23-73-34-400-001 Installation of the CIDS Director (101RH,102RH) ASM 26-16/02
3. Fault Confirmation
__________________
R A. If the PFR shows the CIDS(101RH)-SDF1 or CIDS(102RH)-SDF2 message: R
R (1) Do the SYSTEM TEST of the CIDS-SDF system. R
R (a) On the MCDU:
- Set the "SYSTEM REPORT / TEST" page
- Set the "FIRE PROT" page
- Set the"SMOKE" (or "SDCU" and on the subsequent page "NEXT PAGE" as specified by the installed CFDIU-standard) page
- Set the "SYSTEM TEST" page in the CIDS-SDF menu. R
4. Fault Isolation
_______________
A. If the test gives a different maintenance message:
- Do the trouble shooting procedure related to the maintenance message.
B. One of the these procedures is applicable:
(1) If the test gives the maintenance message: CHECK SDF1 BITE/CIDS(101RH) - SDF1 or CHECK SDF2 BITE/CIDS(102RH) - SDF2:
(a) Open the C/B 15WH and 17WH of the CIDS - SDF1.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 FIRE PROTECTION 防火(93)