A. If there are odours and mist:
- carefully examine the APU externally and make sure that you do not find leaks on the oil system components or oil lines.
(1) If you do not find external oil leaks:
- remove the line between the APU and the APU BLEED VALVE.
- check the contamination (Ref. TASK 49-00-00-810-946).
(a) If the fault continues:
- decontaminate the lines (Ref. AMM TASK 21-00-00-615-001) or (Ref. AMM TASK 21-00-00-615-002).
R **ON A/C 106-149, 211-299, 301-399, 401-499,
A. If there are odours and mist:
- carefully examine the APU externally and make sure that you do not find leaks on the oil system components or oil lines.
(1) If you do not find external oil leaks:
- remove the line between the APU and the APU BLEED VALVE.
- check the contamination (Ref. TASK 49-00-00-810-921).
(a) If the fault continues:
- decontaminate the lines (Ref. AMM TASK 21-00-00-615-001) or (Ref. AMM TASK 21-00-00-615-002).
**ON A/C ALL
B. Table of the circuit breakers used in this procedure:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU FWS/FWC1/SPLY 3WW F01 121VU EIS/FWC2/SPLY 2WW Q07
C. Test
(1) Reset of the FWC1 and FWC2
NOTE : Open the circuit breakers for some seconds before you close
____
them.
(a) Open this(these) circuit breaker(s):
1 2WW
_
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞26-15-00∞∞∞∞∞∞∞∞∞∞Page 207
Aug 01/05 CES_
(b) Close this(these) circuit breaker(s):
1 2WW
_
2 3WW
_
(2) Do the ground scanning of the central warning system (Ref. AMM TASK 31-50-00-710-001).
CARGO COMPARTMENT SMOKE DETECTION - FAULT ISOLATION PROCEDURES
______________________________________________________________
R **ON A/C 004-049, 051-099, 101-105, 151-199, 201-299,
TASK 26-16-00-810-801
FWD LDCC Smoke Detector(s) Fault
1. Possible Causes
_______________
- SDCU (10WQ)
- cargo smoke detector
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 26-16-00-710-001 Operational Check of Cargo-Compartment
Smoke-Detection by PTT AMM 26-16-15-000-001 Removal of the Cargo Smoke Detectors AMM 26-16-15-400-001 Installation of the Cargo Smoke Detectors AMM 26-17-34-000-001 Removal of the Smoke-Detection Control Unit (SDCU)
(10WQ) AMM 26-17-34-400-001 Installation of the Smoke-Detection Control Unit (SDCU) (10WQ) ASM 26-16/02
3. Fault Confirmation
__________________
A. Test. R
R (1) Open the circuit breakers 11WQ and 12WQ R - Wait 20 seconds R - Close the circuit breakers and wait again 1 minute before start of R the next test.
(2) Do the operational test of the cargo compartment smoke detection (Ref. AMM TASK 26-16-00-710-001).
4. Fault Isolation