(2) If the DISCH legend comes on:
- replace the ENG/APU FIRE PNL (1WD) (Ref. AMM TASK 26-12-12-000-001) and (Ref. AMM TASK 26-12-12-400-001).
(a) If the fault continues:
- do a check and repair the wiring of the FIRE TEST (LOOP A) discrete from the engine 2 FDU (2WD2) to the ENG/APU FIRE panel (1WD) (Ref. ASM 26-12/02).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞26-12-00∞∞∞∞∞∞∞∞∞∞Page 274
Feb 01/04R
CES Loss of the FIRE TEST (LOOP B) Discrete Input from the Engine 2 FDU
1. Possible Causes
_______________
- ENG/APU FIRE PNL (1WD)
- wiring of the 28VDC signal from the circuit breaker 8WD2 to the ENG/APU FIRE panel (1WD)
- wiring of the FIRE TEST (LOOP B) discrete from the engine 2 FDU (2WD2) to the ENG/APU FIRE panel (1WD)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
R AMM 26-12-00-710-001 Operational Check of Loop/Squib AMM 26-12-12-000-001 Removal of the ENG/APU Fire Panel (1WD) AMM 26-12-12-400-001 Installation of the ENG/APU Fire Panel (1WD) ASM 26-12/02
3. Fault Confirmation
__________________
A. Test
(1) Do the operational test of the engine fire and overheat detection (loop/squib) (Ref. AMM TASK 26-12-00-710-001).
4. Fault Isolation
_______________
A. If the ENG 2 FIRE indication does not come into view on the upper ECAM DU:
- do a check to see if the DISCH legend of the ENG 2 AGENT 1 pushbutton switch on the ENG/APU FIRE panel (1WD) comes on during the fire test.
(1) If the DISCH legend does not come on:
- replace the ENG/APU FIRE PNL (1WD) (Ref. AMM TASK 26-12-12-000-001) and (Ref. AMM TASK 26-12-12-400-001).
(a) If the fault continues:
- do a check and repair the wiring of the 28VDC signal from the circuit breaker 8WD2 to the ENG/APU FIRE panel (1WD), pin D/M (Ref. ASM 26-12/02).
(2) If the DISCH legend comes on:
- replace the ENG/APU FIRE PNL (1WD) (Ref. AMM TASK 26-12-12-000-001) and (Ref. AMM TASK 26-12-12-400-001).
(a) If the fault continues:
- do a check and repair the wiring of the FIRE TEST (LOOP B) discrete from the engine 2 FDU (2WD2) to the ENG/APU FIRE panel (1WD) (Ref. ASM 26-12/02).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞26-12-00∞∞∞∞∞∞∞∞∞∞Page 276
Feb 01/04R
CES Loss of the INOP LOOP A Discrete from the Engine 1 FDU
1. Possible Causes
_______________
- FDU-ENG1 (2WD1)
- wiring of the INOP LOOP A discrete from the engine 1 FDU (2WD1) to the first terminal block
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 26-12-00-710-002 Operational Test of the Engine Fire and Overheat Detection with the Centralized Fault Display System (CFDS)
AMM 26-12-34-000-001 Removal of the Engine Fire-Detection Unit (FDU) (2WD1,2WD2) AMM 26-12-34-400-001 Installation of the Engine Fire-Detection Unit (FDU) (2WD1,2WD2) ASM 26-12/01
3. Fault Confirmation
__________________
A. Test
(1) Do the operational test of the engine fire and overheat detection from the Multipurpose Control and Display Unit (MCDU) (Ref. AMM TASK 26-12-00-710-002).
4. Fault Isolation
_______________
A. If the test gives the maintenance message CHECK FDU ENG 1 LOOP A WARN CKT:
- replace the FDU-ENG1 (2WD1) (Ref. AMM TASK 26-12-34-000-001) and (Ref. AMM TASK 26-12-34-400-001).
(1) If the fault continues:
- do a check and repair the wiring of the INOP LOOP A discrete from the engine 1 FDU (2WD1) to the first terminal block (Ref. ASM 26-12/01).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : ALL ∞∞26-12-00∞∞∞∞∞∞∞∞∞∞Page 277
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 FIRE PROTECTION 防火(54)