(a) If the fault continues:
- do a check for a ground signal at the pin A/3 of the engine 1 fire extinguishing bottle 1 (Ref. ASM 26-21/01).
1_ If there is no ground signal:
- repair the above wiring.
2_ If there is a ground signal:
- do a check and repair the wiring of the HP discrete signal
from the engine 1 fire extinguishing bottle 1 to the ENG/APU
FIRE panel (1WD), from pin A/2 to pin A/K (Ref. ASM 26-
21/01).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞26-21-00∞∞∞∞∞∞∞∞∞∞Page 232
May 01/03R
CES The DISCH Legend of the ENG 1/AGENT 2 Pushbutton Switch Stays on
1. Possible Causes
_______________
- BOTTLE 2-FIRE EXTING, ENG 1 (8WE1)
- ENG/APU FIRE PNL (1WD)
- ground signal at the pin A/3 of the engine 1 fire extinguishing bottle 2
- wiring of the HP discrete signal from the engine 1 fire extinguishing bottle 2 to the ENG/APU FIRE panel
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 26-12-12-000-001 Removal of the ENG/APU Fire Panel (1WD)
AMM 26-12-12-400-001 Installation of the ENG/APU Fire Panel (1WD)
AMM 26-21-41-000-001 Removal of the Engine Fire-Extinguisher Bottle
(6WE1,8WE1,6WE2,8WE2) AMM 26-21-41-400-001 Installation of the Engine Fire-Extinguisher Bottle (6WE1,8WE1,6WE2,8WE2) ASM 26-21/01
3. Fault Confirmation
__________________
A. Test
Not applicable, the fault is evident.
4. Fault Isolation
_______________
A. If the DISCH legend of the ENG 1/AGENT 2 pushbutton switch does not go off:
- disconnect the electrical connector 8WE1-A from the engine 1 fire extinguishing bottle 2
- do a check for continuity between the pins A/2 and A/3 of the engine 1 fire extinguishing bottle 2.
(1) If there is no continuity:
- replace the BOTTLE 2-FIRE EXTING, ENG 1 (8WE1) (Ref. AMM TASK 26-21-41-000-001) and (Ref. AMM TASK 26-21-41-400-001).
(2) If there is continuity:
- connect the electrical connector 8WE1-A on the engine 1 fire extinguishing bottle 2
- replace the ENG/APU FIRE PNL (1WD) (Ref. AMM TASK 26-12-12-000-001) and (Ref. AMM TASK 26-12-12-400-001).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞26-21-00∞∞∞∞∞∞∞∞∞∞Page 233
May 01/03R CES
(a) If the fault continues:
- do a check for a ground signal at the pin A/3 of the engine 1 fire extinguishing bottle 2 (Ref. ASM 26-21/01).
1_ If there is no ground signal:
- repair the above wiring.
2_ If there is a ground signal:
- do a check and repair the wiring of the HP discrete signal
from the engine 1 fire extinguishing bottle 2 to the ENG/APU
FIRE panel, from pin A/2 to pin B/K (Ref. ASM 26-21/01).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞26-21-00∞∞∞∞∞∞∞∞∞∞Page 234
May 01/03R
CES The DISCH Legend of the ENG 2/AGENT 1 Pushbutton Switch Stays on
1. Possible Causes
_______________
- BOTTLE 1-FIRE EXTING, ENG 2 (6WE2)
- ENG/APU FIRE PNL (1WD)
- ground signal at the pin A/3 of the engine 2 fire extinguishing bottle 1
- wiring of the HP discrete signal from the engine 2 fire extinguishing bottle 1 to the ENG/APU FIRE panel
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 26-12-12-000-001 Removal of the ENG/APU Fire Panel (1WD)
AMM 26-12-12-400-001 Installation of the ENG/APU Fire Panel (1WD)
AMM 26-21-41-000-001 Removal of the Engine Fire-Extinguisher Bottle
(6WE1,8WE1,6WE2,8WE2) AMM 26-21-41-400-001 Installation of the Engine Fire-Extinguisher Bottle (6WE1,8WE1,6WE2,8WE2) ASM 26-21/01 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320 Trouble Shooting Manual 排故手册 FIRE PROTECTION 防火(105)