3. Fault Confirmation
__________________
A. Do the pre-conditioning with the APU (Ref. AMM TASK 12-33-21-618-001).
4. Fault Isolation
_______________
R **ON A/C 001-049, 051-099, 101-105, 151-199, 201-210,
A. If you smell fumes in the cabin during the pre-conditioning with the APU:
(1) Do the related trouble shooting procedure for the fumes in the cabin/oil smoke at the APU exhaust:
- For the GTCP 36-300 (Ref. TASK 49-00-00-810-846) or
- For the APS 3200 (Ref. TASK 49-00-00-810-921) or
- For the 131-9(A) (Ref. TASK 49-00-81-810-874).
NOTE : An Oil leak of the APU causes this fault.
____
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-105, 151-199, ∞∞26-16-00∞∞∞∞∞∞∞∞∞∞Page 205
201-299, May 01/05 CES
A. If you smell fumes in the cabin during the pre-conditioning with the APU:
(1) Do the related trouble shooting procedure for the fumes in the cabin/oil smoke at the APU exhaust:
- For the GTCP 36-300 (Ref. TASK 49-00-00-810-846) or
- For the APS 3200 (Ref. TASK 49-00-00-810-921) or
- For the 131-9(A) (Ref. TASK 49-00-81-810-874).
NOTE : An Oil leak of the APU causes this fault.
____
R **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
5. Close-up
________
A. Put the aircraft back to its initial configuration.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-105, 151-199, ∞∞26-16-00∞∞∞∞∞∞∞∞∞∞Page 206
201-299, May 01/05 CES
SMOKE Indicator Light inoperative
1. Possible Causes_______________
- SDCU (10WQ)
- bulbs
- wiring
2. Job Set-up Information______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 26-16-00-710-001 Operational Check of Cargo-Compartment Smoke-Detection by PTT
AMM 26-17-34-000-001 Removal of the Smoke-Detection Control Unit (SDCU) (10WQ)
AMM 26-17-34-400-001 Installation of the Smoke-Detection Control Unit (SDCU) (10WQ)
AMM 33-14-00-710-001 Operational Test of the Annunciator Light Test System in the Cockpit
ASM 26-16/01
TSM 33-14-00-810-801 Failure of One Annunciator Light Only
3. Fault Confirmation__________________
A. Test Do the Operational Test of the Cargo-Compartment Smoke-Detection System by PPT (Ref. AMM TASK 26-16-00-710-001).
4. Fault Isolation_______________
A. If one SMOKE indicator light does not come on during the test:
- do the Operational Test of the Annunciator Light Test System in the Cockpit (Ref. AMM TASK 33-14-00-710-001).
(1) If the fault continues:
- replace the related bulbs.
(a) If the fault continues: (Ref. TSM TASK 33-14-00-810-801).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-105, 151-199, ∞∞26-16-00∞∞∞∞∞∞∞∞∞∞Page 207
201-299, May 01/05 CES
(2) If the Annunciator Light Test is OK:
- replace the SDCU (10WQ) (Ref. AMM TASK 26-17-34-000-001) and (Ref. AMM TASK 26-17-34-400-001).
(a) If the fault continues:
- do a check and repair the wiring if necessary between the SDCU (10WQ) and the relay board (3LP) (Ref. ASM 26-16/01)
B. Do the test given in para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-105, 151-199, ∞∞26-16-00∞∞∞∞∞∞∞∞∞∞Page 208
201-299, May 01/05 CES
R **ON A/C 106-149, 301-399, 401-499,
TASK 26-16-00-810-809
Both Smoke-Detectors of one AFT LDCC Cavity Inoperative
1. Possible Causes
_______________
- AFT LDCC smoke-detectors
2. Job Set-up Information
______________________
A. Referenced Information