(f) Open the SDCU circuit breakers 11WQ and 12WQ. R NOTE : If the measurements of step (e) are done after short
____ R intervals it is not necessary to do step (f). If not, do R the step (d) again.
R (g) Connect the red lead of the DC meter to the pin A and the black R lead to the pin B of the aircraft-side connector of the detector.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-105, 151-199, ∞∞26-17-00∞∞∞∞∞∞∞∞∞∞Page 211
201-299, May 01/05 CES
R (h) During the subsequent 40 to 60 seconds do a check of the voltage
R with the voltage-meter. The DC meter pulses between DC voltages.
1_ If the highest voltage peak shown on the voltmeter is less
than 22VDC,
R - For A319/320: one or more of the smoke detector(s) between
R SDCU channel 1 and 5WH is(are) defective.
R - For A321: one or more of the smoke detector(s) between the
R SDCU channel 1 and 7WH is(are) defective.
2 If the highest voltage peak shown on the voltmeter is equal to
_
24+/-2V (voltage pulses between 0V and 24V), R - For A319/320: the smoke detectors between SDCU channel 1 and R 5WH are serviceable. Smoke detector 5WH apparently is
defective. Replace the smoke detector. R - For A321: the smoke detectors between SDCU channel 1 and 7WH R are serviceable. Smoke detector 7WH apparently is defective.
Replace the smoke detector.
(i) Open the SDCU circuit breakers 11WQ and 12WQ.
R (j) Connect smoke detector 5WH for A319/A320 (or 7WH for A321) to the R loop again.
R (k) If step (e) 1 applies, do a test for each smoke detector in the R sequence of channel 2, that is between SDCU channel 2 and 5WH for A319/320, between SDCU channel 2 and 7WH for A321.
R NOTE : The test for the last smoke detector is complete when the
____ R smoke detector 5WH for A319/A320 or 7WH for A321 was R disconnected and connected to the loop again.
1 Disconnect the n-th smoke detector of channel 2.
_
NOTE : "n" gives the position of the smoke detector in the
____ loop. At the start of this procedure "n" refers to the second cargo smoke detector, n=2. Cargo smoke detector 2WH (n=2) is disconnected to examine the previous
R detector 1WH (n-1) in the loop (adjacent to 2WH).
R 2_ Close the SDCU circuit breakers 11WQ and 12WQ and pause 40 toR 60 seconds.
3 Measure the voltage (DC mode) between pin F and pin G of the
_ aircraft-side connector.
a If the highest voltage peak shown on the voltmeter is less
_ R than 22VDC, the smoke detector in the location (n-1) is R defective. Replace the smoke detector.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-105, 151-199, ∞∞26-17-00∞∞∞∞∞∞∞∞∞∞Page 212
201-299, May 01/05 CES
b_ If the highest voltage peak shown on the voltmeter is equal
R to 24+/-2V (voltage level pulses between 0V and 24V), the
R smoke detector on the location (n-1) is serviceable.
4_ Open the SDCU circuit breaker 11WQ and 12WQ.
R 5_ Connect the n-th smoke detector to the loop again and
R disconnect the smoke detector on the location (n+1).
R 6_ Do the steps (k) 1 to step (k) 5 for each smoke detector that
R is in a subsequent position in the loop to examine each smoke
R detector.
R NOTE : An incorrect voltage measured at the location number n____
R indicates a defective smoke detector on the location
R (n-1).
R (l) If step (h) 1 applies, do a test for each smoke detector in the
R sequence of channel 1. That is between SDCU channel 1 and 5WH for
R A319/320, between SDCU channel 1 and 7WH for A321.
R NOTE : The test for the last smoke detector is complete when____
R smoke detector 5WH for A319/320 or 7WH for A321 has been
R disconnected and connected to the loop again.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 FIRE PROTECTION 防火(86)