R Cargo Compartment Smoke Detection - Block Diagram R Figure 302
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 301-399, ∞∞26-16-00∞∞∞∞∞∞∞∞∞∞Page 304
May 01/04 CES
Cargo-Compartment Smoke Detector - Visual Identification
Figure 303
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-105, 151-199, ∞∞26-16-00∞∞∞∞∞∞∞∞∞∞Page 305
201-299, May 01/05 CES
LAVATORY SMOKE DETECTION - FAULT ISOLATION PROCEDURES
_____________________________________________________
R **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
TASK 26-17-00-810-801
Lavatory Smoke Detection Fault
1. Possible Causes
_______________
- lavatory smoke detector
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 26-17-00-710-001 AMM 26-17-15-000-001 AMM 26-17-15-400-001 Operational Test of the Lavatory Smoke-Detection SystemRemoval of the Lavatory Smoke Detector 1WQInstallation of the Lavatory Smoke Detector 1WQ
3. Fault Confirmation__________________
R A. Test:
R R R R (1) - Open the circuit breakers 11WQ and 12WQ - Wait 20 seconds - Close the circuit breakers and wait again 1 minute before start of the next test.
(2) Do the operational test of the lavatory smoke-detection system (Ref. AMM TASK 26-17-00-710-001).
4. Fault Isolation_______________
R R R A. If the test gives a different maintenance message: - Do the trouble shooting procedure related to the maintenance message.
B. If the test gives the maintenance message TEST OK, no other maintenance action is necessary.
C. If the test gives the maintenance message SMOKE DET LAV X (YWQ):
NOTE : X/Y shows the related lavatory location.
____
- replace the related lavatory smoke detector (Ref. AMM TASK 26-17-15-000-001) and (Ref. AMM TASK 26-17-15-400-001).
D. Do the test as given in the Para. 3.
5. Close-up
________
A. Put the aircraft back to its initial configuration.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-105, 151-199, ∞∞26-17-00∞∞∞∞∞∞∞∞∞∞Page 202
201-299, May 01/05 CES
SDCU Single Channel Fault
1. Possible Causes
_______________
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 26-17-15-000-001 AMM 26-17-15-400-001 AMM 31-32-00-860-005 ASM 26-16/02 ASM 26-17/02 Removal of the Lavatory Smoke Detector 1WQInstallation of the Lavatory Smoke Detector 1WQProcedure to Get Access to the SYSTEM REPORT/TEST FIRE PROT Page
3. Fault Confirmation__________________
R A. Test:
R (1) - Open the circuit breakers 11WQ and 12WQ
R - Wait 20 seconds
R - Close the circuit breakers and wait again 1 minute before start of
R the next test.
R (2) Get access to the MCDU/SDCU menu page (Ref. AMM TASK 31-32-00-860-
005):
R - Push the line key adjacent to the <ON GROUND FAULTS indication.
R
R The MCDU shows the fault message. If there is no fault, the MCDU
R shows NO FAILURE.
4. Fault Isolation_______________
R A. If the test gives a different maintenance message:
R - Do the trouble shooting procedure related to the maintenance message.
R
B. If the test gives the maintenance message TEST OK, no other maintenance
action is necessary.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-105, 151-199, ∞∞26-17-00∞∞∞∞∞∞∞∞∞∞Page 203
201-299, May 01/05 CES