R A. If the test gives a different maintenance message:
R - Do the trouble shooting procedure related to the maintenance message.
R

 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞26-16-00∞∞∞∞∞∞∞∞∞∞Page 201
 May 01/05 CES B. If the test is OK:

 

 - no other maintenance action is necessary.
 C. If the test gives the maintenance message SMOKE DET X WH FWD LDCC (X = RESP. DETECTOR):
 - replace the related cargo smoke detector (Ref. AMM TASK 26-16-15-000-001) and (Ref. AMM TASK 26-16-15-400-001).
 (1) If the fault continues:

 - do a check and repair the wiring if necessary between the SDCU connected cargo compartment smoke detectors (Ref. ASM 26-16/02).

 (2) If the fault continues:


 - replace the SDCU (10WQ) (Ref. AMM TASK 26-17-34-000-001) and (Ref. AMM TASK 26-17-34-400-001).
 D. Do the test given in para. 3.
 5. Close-up
________
 A. Put the aircraft back to its initial configuration.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 004-049, 051-099, 101-105, 151-199, ∞∞26-16-00∞∞∞∞∞∞∞∞∞∞Page 202
 201-299, May 01/05 CES

 

R **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
 TASK 26-16-00-810-802
 AFT LDCC Smoke Detector(s) Fault
 1. Possible Causes
_______________
 - SDCU (10WQ)

 - cargo smoke detector

 - wiring


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 26-16-00-710-001 AMM 26-16-15-000-001
AMM 26-16-15-400-001 AMM 26-17-34-000-001 AMM 26-17-34-400-001 ASM 26-16/02
 3. Fault Confirmation
__________________
 A. Test. R
Operational Check of Cargo-Compartment Smoke-Detection by PTTRemoval of the Cargo Smoke DetectorsInstallation of the Cargo Smoke DetectorsRemoval of the Smoke-Detection Control Unit (SDCU) (10WQ)Installation of the Smoke-Detection Control Unit (SDCU) (10WQ)
R (1) Open the circuit breakers 11WQ and 12WQ R - Wait 20 seconds R - Close the circuit breakers and wait again 1 minute before start of R the next test.
 (2) Do the operational test of the cargo compartment smoke detection (Ref. AMM TASK 26-16-00-710-001).
 4. Fault Isolation
_______________
R A. If the test gives a different maintenance message:
R - Do the trouble shooting procedure related to the maintenance message.
R

 B. If the test is OK:
 - no other maintenance action is necessary.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-105, 151-199, ∞∞26-16-00∞∞∞∞∞∞∞∞∞∞Page 203
 201-299, May 01/05 CES

 

 C. If the test gives the maintenance message SMOKE DET X WH AFT LDCC (X = RESP. DETECTOR):
 - replace the related cargo smoke detector (Ref. AMM TASK 26-16-15-000-001) and (Ref. AMM TASK 26-16-15-400-001).
 (1) If the fault continues:

 - do a check and repair the wiring if necessary between the SDCU connected cargo compartment smoke detectors (Ref. ASM 26-16/02).

 (2) If the fault continues:


 - replace the SDCU (10WQ) (Ref. AMM TASK 26-17-34-000-001) and (Ref. AMM TASK 26-17-34-400-001).
 D. Do the test given in para. 3.
 5. Close-up
________
 A. Put the aircraft back to its initial configuration.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-105, 151-199, ∞∞26-16-00∞∞∞∞∞∞∞∞∞∞Page 204
 201-299, May 01/05 CES

 


 Cargo-Compartment Smoke Warning(s) without Fire
 1. Possible Causes
_______________
 - Oil leak of the APU
 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
49-00-00-810-846 Fumes in the Cabin/Oil Smoke at the APU Exhaust (GTCP 36-300) 49-00-00-810-921 Fumes in the Cabin/Oil Smoke at the APU Exhaust (APS
 