R **ON A/C 106-149, 301-399, 401-499,
TASK 26-23-00-810-807
Fire-Extinguisher Bottle 1 FWD-SQUIB Fault
1. Possible Causes
_______________
- CARTRIDGE FWD, BOTTLE 1 (4003WX)
- DIR-CIDS, 1 (101RH)
- DIR-CIDS, 2 (102RH)
- wiring
- P/B switch DISCH (3WX)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 23-73-34-000-001 Removal of the CIDS Director (101RH,102RH)
AMM 23-73-34-400-001 Installation of the CIDS Director (101RH,102RH)
AMM 26-23-00-710-001 Operational Test of the Cargo-Compartment
Fire-Extinguishing System
AMM 26-23-41-000-005 Removal of the Cartridge of the Cargo
Fire-Extinguisher Bottle
AMM 26-23-41-400-005 Installation of the Cartridge of the Cargo
Fire-Extinguisher Bottle
ASM 26-23/01
3. Fault Confirmation
__________________
A. Do the operational test of the cargo-compartment fire-extinguishing system (Ref. AMM TASK 26-23-00-710-001).
4. Fault Isolation
_______________
A. If the test gives a different maintenance message:
- Do the trouble shooting procedure related to the maintenance message.
B. If the test gives the maintenance message CRG FIRE BTL 1 FWD SQUIB:
- replace the CARTRIDGE FWD, BOTTLE 1 (4003WX) (Ref. AMM TASK 26-23-41-000-005) and (Ref. AMM TASK 26-23-41-400-005).
(1) If the fault continues:
- replace the DIR-CIDS, 1 (101RH) (Ref. AMM TASK 23-73-34-000-001) and (Ref. AMM TASK 23-73-34-400-001).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 106-149, 301-399, 401-499, ∞∞26-23-00∞∞∞∞∞∞∞∞∞∞Page 207
Aug 01/05 CES
(2) If the fault continues:
- replace the DIR-CIDS, 2 (102RH) (Ref. AMM TASK 23-73-34-000-001) and (Ref. AMM TASK 23-73-34-400-001).
(3) If the fault continues:
- do a check and repair the wiring between the: BOTTLE 1 (4005WX) connector C/B and CIDS DIR 1 (101RH) connector AA/4B, BOTTLE 1 (4005WX) connector C/B and CIDS DIR 2 (102RH) connector AA/4B, BOTTLE 1 (4005WX) connector C/A and GND (Ref. ASM 26-23/01).
(4) If the fault continues:
- do a check of the P/B switch DISCH (3WX) and replace it if necessary (Ref. ASM 26-23/01).
C. Do the test given in para. 3.
5. Close-up
________
A. Put the aircraft back to its initial configuration.
Fire-Extighuisher Bottle 1 AFT-SQUIB Fault
1. Possible Causes
_______________
- CARTRIDGE FWD, BOTTLE 1 (4003WX)
- DIR-CIDS, 1 (101RH)
- DIR-CIDS, 2 (102RH)
- wiring
- P/B switch DISCH (3WX)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 23-73-34-000-001 Removal of the CIDS Director (101RH,102RH)
AMM 23-73-34-400-001 Installation of the CIDS Director (101RH,102RH)
AMM 26-23-00-710-001 Operational Test of the Cargo-Compartment
Fire-Extinguishing System
AMM 26-23-41-000-005 Removal of the Cartridge of the Cargo
Fire-Extinguisher Bottle
AMM 26-23-41-400-005 Installation of the Cartridge of the Cargo
Fire-Extinguisher Bottle
ASM 26-23/01
3. Fault Confirmation
__________________
A. Do the operational test of the cargo-compartment fire-extinguishing system (Ref. AMM TASK 26-23-00-710-001).
4. Fault Isolation
_______________
A. If the test gives a different maintenance message:
- Do the trouble shooting procedure related to the maintenance message.
B. If the test gives the maintenance message CRG FIRE BTL 1 FWD SQUIB:
- replace the CARTRIDGE FWD, BOTTLE 1 (4003WX) (Ref. AMM TASK 26-23-41-000-005) and (Ref. AMM TASK 26-23-41-400-005).