Not serviceable.
Less than 30 percent of first thread is damaged.
Less than 10 percent of second thread is damaged.
Damage is more than the above limits.
Not servceable.
Not serviceable.
Not serviceable
Not serviceable.
Repair lead (Ref. TASK 74-21-10-300-006).
Chase the threads.
Chase the threads.
Replace lead (Ref. TASK 74-21-10-000-002) and (Ref. TASK 74-21-10-400-002).
Repair the lead (Ref. TASK 74-21-10-300-006).
Repair the lead (Ref. TASK 74-21-10-300-006).
Replace lead (Ref. TASK 74-21-10-000-002) and (Ref. TASK 74-21-10-400-002).
Repair the lead (Ref. TASK 74-21-10-300-006).
F 『 EEFF : ALL E Page 60774-21-10
E E Aug 01/01 E E ECES E
F 『
E C F M E
E E
E 56-5B E
E E
-------------------------------------------------------------------------------INSPECT/CHECK MAXIMUM REMARKS SERVICEABLE LIMITS -------------------------------------------------------------------------------
R R R R NOTE: The white and blue silicone seals are not interchangeable.
R R R 4. Type 3 and 4 igniter lead braided conduit for:
R R R - Chafing along the entire length of the ignition lead.
R R R R - Broken strands.
R R R R
R R R R
R R R
R R R - Braze joint separation.
R R - Sharp bends.
Not serviceable.
Less than half of the circumference by 25.4 mm (1.0000 in.) in length is permitted.
Less than 25.4 mm (1.0000 in.) in length within any 76.2 mm (3.0000 in.) of lead.
Total damage can not be more than 10 percent of the total length of the lead.
No damage to conduit under the strands.
Not serviceable.
Maximum 152.4 mm (6.0000 in.) bend radius.
Replace lead (Ref. TASK 74-21-10-000-002) and (Ref. TASK 74-21-10-400-002).
Replace lead (Ref. TASK 74-21-10-000-002) and (Ref. TASK 74-21-10-400-002).
Replace lead (Ref. TASK 74-21-10-000-002) and (Ref. TASK 74-21-10-400-002).
Replace lead (Ref. TASK 74-21-10-000-002) and (Ref. TASK 74-21-10-400-002).
Replace lead (Ref. TASK 74-21-10-000-002) and (Ref. TASK 74-21-10-400-002).
Replace lead (Ref. TASK 74-21-10-000-002) and (Ref. TASK 74-21-10-400-002).
Reposition the lead to eliminate sharp bend.
F 『 EEFF : ALL E Page 60874-21-10
E E Aug 01/01 E E ECES E
F 『
E C F M E
E E
E 56-5B E
E E
-------------------------------------------------------------------------------INSPECT/CHECK MAXIMUM REMARKS SERVICEABLE LIMITS -------------------------------------------------------------------------------
R 5. Type 3 and 4 cooling R shroud for :
R A. Obstruction at exit holes.
R 6. Type 3 and 4 ignition R lead chafe guard for
R :
R R - Cuts and/or tears. R R Subtask 74-21-10-420-059
Not serviceable. Remove the obstruction.
Not serviceable. Repair lead (Ref. TASK 74-
21-10-300-007).
R D. Connect the right ignition lead connector (Ref. TASK 74-21-10-400-002).
5. Close-up
________
Subtask 74-21-10-410-055
A. Close Access
(1) Make sure that the work area is clean and clear of tool(s) and other items.
(2) Close the thrust reverser doors: (Ref. TASK 78-36-00-410-040). FOR 1000EM1 451AL, 452AR FOR 1000EM2 461AL, 462AR
Subtask 74-21-10-440-052
B. Make the thrust reverser serviceable (Ref. TASK 78-30-00-081-041).
F 『 EEFF : ALL E Page 60974-21-10
E E Aug 01/01 E E ECES E Subtask 74-21-10-410-056
F 『
E C F M E
E E
E 56-5B E
E E
C. Close Access
(1) Close the fan cowl doors: (Ref. TASK 71-13-00-410-040) FOR 1000EM1 437AL, 438AR FOR 1000EM2 447AL, 448AR
(2) Remove the warning notice(s).
Subtask 74-21-10-865-059
D. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 1JH FOR 1000EM1 2JH1, 3JH1 FOR 1000EM2 2JH2, 3JH2
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM IGNITION 点火(21)