(c)
Make sure the fluid flow stops about 0.4 second after you pushed the switch.
S 862-054-001
(12)
Release the RAIN REPELLENT R switch.
S 092-072-001
(13)
Remove the plastic bags from the rain repellent nozzles.
S 102-055-001
CAUTION: REMOVE THE REPELLENT FLUID FROM THE AIRPLANE SKIN AND GLASS
_______ IMMEDIATELY. THE REPELLENT FLUID CAN CAUSE A STAIN.
(14)
Immediately and fully clean the airplane skin and windows to remove repellent fluid (AMM 12-25-01/301).
S 212-073-001
(15)
Make sure there is a strong flow of air at the rain repellent nozzles.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ALL ú
30-43-00
ú CONFIG ú 05 Page 210 ú Jan 28/01
A
757 MAINTENANCE MANUAL
S 212-056-001
(16)
Make sure there is no leakage under the center instrument panels P1, P2, and P3.
S 212-057-001
(17)
Make sure there are no leaks around the rain repellent bottle or receptacle.
S 212-058-001
(18)
Make sure the rain repellent fluid level is above the replacement level in the sight gage.
S 962-059-001
(19)
Replace the bottle, if necessary (AMM 12-16-01/301).
S 212-060-001
(20)
Make sure the rain repellent fluid pressure gage indicator is in the green band.
S 962-061-001
(21)
Replace the bottle, if necessary (AMM 12-16-01/301).
E. Put the Airplane Back to Its Usual Condition
S 862-062-001
(1)
If the APU was used as the air source, push the APU switch, on the bleed air supply panel M10259 (panel P5), to the OFF position.
S 862-071-001
(2)
Shut down the APU (AMM 49-11-00/201) or turn off the ground
pneumatic source (AMM 36-00-00/201).
(3)
Remove electrical power, if it is not necessary (AMM 24-22-00/201).
S 862-064-001
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ALL ú
30-43-00
ú CONFIG ú 02 Page 211 ú May 28/99
A
757 MAINTENANCE MANUAL
WINDSHIELD RAIN REPELLENT SYSTEM - MAINTENANCE PRACTICES
________________________________________________________
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:757 AMM 飞机维护手册 防冰和排雨 CHAPTER 30 - ICE AND RAIN PROTECTION(161)