• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-10-27 13:25来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

A00247 Sealing Compound - BMS 5-95, Class B

 (2)  
B00083 Aliphatic Naphtha - TT-N-95

 (3)  
A00311 Adhesive - Rubber Cement B F Goodrich #4


 C. Parts
 ~.............................................................................. | AMM | | AIPC | ................. NOMENCLATURE ............................ | FIG | ITEM | | SUBJECT | FIG | ITEM | ................................................................................ | 401 | 1 | Motor/Converter (Left Side) | 30-42-01 | 05 | 25 | | | 1 | Motor/Converter (Right Side) | | | 30 | | | 3 | Gasket (Left Side) | | | 40 | | | 3 | Gasket (Right Side) | | | 45 | 2.......….......…...................................…...........….....…........1
 D. References
 (1)  
AMM 24-22-00/201, Electrical Power - Control

 (2)  
AMM 30-42-03/401, Windshield Wiper Arm/Blade - Removal/Installation


 E. Access
 (1)  Location Zones
 211/212 Control Cabin - Section 41

 F. Procedure
 S 034-014
 (1)  Remove the sealing compound from the access opening with an aerodynamic-smoother cutting tool.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 30-42-02
 ALL  ú ú 01 Page 403 ú May 28/01

A

757
MAINTENANCE MANUAL

 (2)  S 114-015Clean the access opening with a varnish brush and fresh aliphatic naphtha. (a) Rub the opening with a clean cloth before the aliphatic naphtha dries.
 (3)  S 394-016Use a brush to apply a light layer of rubber cement to the panel. This bonds the gasket (3) to the motor/converter (1). (a) Let the rubber cement dry for approximately 15 minutes.
 (4)  S 434-017Connect the electrical connector to the motor/converter (1).
 (5)  S 424-018Install the motor/converter (1).
 S 434-019

 CAUTION: MAKE SURE YOU INSTALL THE BOLTS IN THE CORRECT POSITIONS.
_______ BOLTS INSTALLED INCORRECTLY CAN CAUSE DAMAGE TO THE EQUIPMENT.
 (6)  
Install the bolts (4).

 S 864-020

 (7)  
Supply electrical power (AMM 24-22-00/201).

 S 864-021

 (8)  
If you replaced the left motor/converter (1), remove the DO-NOT-CLOSE tag and close this circuit breaker on the P11 panel:


 (a)  11R13, WSHLD WIPER LEFT
 S 864-022
 (9)  If you replaced the right motor/converter (1), remove the DO-NOT-CLOSE tag and close this circuit breaker on the P11 panel:
 (a)  11R22, WSHLD WIPER RIGHT
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:757 AMM 飞机维护手册 防冰和排雨 CHAPTER 30 - ICE AND RAIN PROTECTION(143)