 B.  Access
 (1)  
Location Zones
 119/120 Main Equipment Center
 211/212 Control Cabin - Section 41


 (2)  
Access Panel
 119BL E/E Bay Access Door

 

 C.  Procedure
 S 014-003
 (1)  
Open the E/E bay access door 119BL (AMM 06-41-00/201).

 S 864-004

 (2)  
If you remove the heat control unit, M191, for the left forward/right side window, do these steps:


 (a)  Open these circuit breakers on the miscellaneous electrical equipment panel, P70, and attach DO-NOT-CLOSE tags: 1) 70A3, WINDOW HTR 2R 2) 70A4, WINDOW HTR 3R 3) 70C13, WINDOW HTR L
 S 864-006
 (3)  If you remove the heat control unit, M192, for the right forward/left side window, do this step:
 (a)  Open these circuit breakers on the right miscellaneous electrical equipment panel, P37, and attach DO-NOT-CLOSE tags: 1) 37E3, WINDOW HTR 2L 2) 37E4, WINDOW HTR 3L 3) 37J2, WINDOW HTR 1R
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 30-41-01
 ALL  ú ú 03 Page 401 ú Sep 28/01

A

757 MAINTENANCE MANUAL
 S 014-007
 (4)  Get access to the heat control units (WHCU) in the main E/E equipment bay.
 NOTE: WHCU M191 is on shelf E1-2 and WHCU M192 is on shelf E1-1.
____
 S 024-008
 CAUTION: DO NOT TOUCH THE HEAT CONTROL UNITS BEFORE YOU DO THE PROCEDURE
_______ FOR DEVICES THAT ARE SENSITIVE TO ELECTROSTATIC DISCHARGE (AMM 20-41-01/201). ELECTROSTATIC DISCHARGE CAN CAUSE DAMAGE TO THE HEAT CONTROL UNITS.
 (5) Remove the applicable heat control unit (AMM 20-10-01/401).
 TASK 30-41-01-404-009
 3. Install the Heat Control Unit
_____________________________
 A. References
 (1)  
AMM 06-41-00/201, Fuselage (Major Zones 100 and 200) Access Doors and Panels

 (2)  
AMM 20-10-01/401, E/E Rack Mounted Components

 (3)  
AMM 20-41-01/201, Electrostatic Sensitive Devices

 (4)  
AMM 24-22-00/201, Electrical Power - Control


 B. Access
 (1)  
Location Zones
 119/120 Main Equipment Center
 211/212 Control Cabin - Section 41


 (2)  
Access Panel
 119BL E/E Bay Access Door

 

 C. Procedure
 S 424-010
 CAUTION: DO NOT TOUCH THE HEAT CONTROL UNITS BEFORE YOU DO THE PROCEDURE
_______ FOR DEVICES THAT ARE SENSITIVE TO ELECTROSTATIC DISCHARGE (AMM 20-41-01/201). ELECTROSTATIC DISCHARGE CAN CAUSE DAMAGE TO THE HEAT CONTROL UNITS.
 