Page 98.217 D633W101-BEJ Sep 05/2002
CMCS -SPECIAL FUNCTION MAIN DISPLAY
Select OPERATE FUNCTION AGAIN to show the precondition dialog box.
INHIBITED shows when a test inhibit condition exists. The TO START FUNCTION control selection shows adjacent to the message.
The TO START FUNCTION selection in this example causes the function inhibit dialog box to show.
CAN NOT OPERATE shows as the message if a function interference condition exists. The TO START FUNCTION control selection shows adjacent to the message.
The TO START FUNCTION selection in this case causes the function interference dialog box to show.
If the LRU stops the special function, STOPPED shows as the message and TO START FUNCTION shows as the control selection.
Text Field
If the message STOPPED shows in the function condition field, and the user stops the function, or the member system stops the function, then the text field shows one of these messages:
*
User Stopped the Function
*
Member System Stopped the Function.
Text Field Title
When STOPPED shows in the function condition field, the title of the text field is CAUSE.
Buttons
Select NEW FUNCTION to show the special function selection dialog box.
Button
Select NEW FUNCTION to show the special function selection dialog box.
EFFECTIVITY BEJ ALL 45-10-00
Page 98.218
D633W101-BEJ Sep 05/2002
777 AIRCRAFT MAINTENANCE MANUAL
CMCS -SPECIAL FUNCTION MAIN DISPLAY
EFFECTIVITY BEJ ALL 45-10-00
Page 98.219
D633W101-BEJ Sep 05/2002
CMCS -SPECIAL FUNCTION INTERACTIVE DIALOG BOX
General
Interactive dialog boxes show when interaction by the user is necessary to complete the function.
The member systems control the interactive displays. LRUs in the member systems send a control signal that tells the CMCF to show the interactive displays as necessary. When the CMCF gets the control signal, any existing interactive displays close.
Each interactive dialog box has:
*
Dialog box title
*
Function title
*
Messages
*
Buttons
Function Title
The function title shows the title of the function from the initial selection on the special functions selection dialog box.
Messages
The messages area shows directions to complete the function.
The message area also shows any warnings associated with the function.
Buttons
Select CONTINUE to remove the interactive dialog box and the to start the function.
Select STOP FUNCTION to remove the interactive dialog box and to show STOPPED as the FUNCTION CONDITION message on the special function display. The control selection shows OPERATE FUNCTION AGAIN.
Select REPORT DATA to show the report dialog box.
Select HELP to show the help dialog box for the interactive dialog box. Help text for the dialog box must be in the CMCF AMI for HELP to show.
EFFECTIVITY BEJ ALL 45-10-00
Page 98.220
D633W101-BEJ Sep 05/2002
CMCS -SPECIAL FUNCTION INTERACTIVE DIALOG BOX
EFFECTIVITY BEJ ALL 45-10-00
Page 98.221
D633W101-BEJ Sep 05/2002
777 AIRCRAFT MAINTENANCE MANUAL
THIS PAGE IS INTENTIONALLY LEFT BLANK
45-10-00
Page 98.222 D633W101-BEJ Sep 05/2002
CMCS -SPECIAL FUNCTION INHIBIT AND INTERFERENCE DIALOG BOXES
Function Inhibit Dialog Box
When the FUNCTION CONDITION message shows INHIBITED, the control command changes to TO START FUNCTION.
Select TO START FUNCTION to show the function inhibit dialog box.
The dialog box has:
*
Box title
*
Function title
*
Instructions to continue the function
*
Buttons.
The function title shows the title from the original selection on the special function selection dialog box.
The instructions tell why the function is inhibited and how to enable the function.
After the inhibit condition goes away, select CONTINUE to remove the dialog box to enable the function to continue.
Select REPORT DATA to show the report dialog box.
Select HELP to show the help dialog box for the function inhibit dialog box. Help text for the dialog box must be in the CMCF AMI for HELP to show. 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:777 AMM 飞机维护手册 中央维护 Central Maintenance(66)