"IMM" is the bus type
*
"Bite gg1" is the AIMS partition name
*
"940005a0 is the AIMS partition address
*
"4" is the byte selection.
The input destination element identifies the AIMS cabinet as the destination of the signal. Use "L" for the left AIMS cabinet and "R" for the right AIMS cabinet.
The bus type element identifies this as an AIMS IMM signal specification. Use "IMM" to identify this signal specification as AIMS IMM.
The AIMS partition name element is an alphanumeric name that identifies the AIMS partition.
The AIMS partition address element is an eight character hexadecimal number that identifies the partition address. It is not necessary to enter leading zeros.
The byte selection element is the number of bytes of the partition address to monitor. Use 1, 2, or 4.
EFFECTIVITY BEJ ALL 45-10-00
Page 98.144
D633W101-BEJ Sep 05/2002
CMCS -INPUT MONITORING GENERAL INPUT PAGE
EFFECTIVITY BEJ ALL 45-10-00
Page 98.145
D633W101-BEJ Sep 05/2002
CMCS -INPUT MONITORING UNITS DIALOG BOX
General
The input monitoring units dialog box lets you monitor a signal in a unit other than the default unit. The default unit for ARINC 429, ARINC 629, and AIMS IMM is binary.
Analog variables are only in engineering units.
Analog discretes show as open or ground.
The dialog box has:
*
Title
*
Exclusive selections
*
List box
*
Buttons.
Exclusive Selections
These are the seven exclusive selections:
*
Decimal
*
Floating point
*
Engineering
*
Hexadecimal
*
ISO #5
*
Binary
*
Engineering Through Aliases.
The chart shows which selections are available for each signal type.
Select Engineering to permit the entry of data in the text field next to Engineering. The data field has a ten character signal data range field, followed by a two character significant bit field, and then an eight character unit field.
Aliases List Box
The aliases list box is always available for selection. The aliases list box shows all engineering conversions in memory.The engineering conversions are defined in the CPM/COMM operational program software (OPS).
When you select an item in the list box, the Engineering Through Aliases exclusive selection highlights.
Buttons
When you select an exclusive selection, the CONTINUE button becomes available. Select CONTINUE to return to the input monitoring general purpose page. If you select CONTINUE when an invalid entry exists in the text fields, the invalid entry dialog box shows.
Select GO BACK to remove the dialog box and return to the previous display.
Select HELP to show the help dialog box for the input monitoring units dialog box. Help must exist in the CMCF AMI for HELP to show.
EFFECTIVITY BEJ ALL 45-10-00
Page 98.146
D633W101-BEJ Sep 05/2002
777 AIRCRAFT MAINTENANCE MANUAL
CMCS -INPUT MONITORING UNITS DIALOG BOX
EFFECTIVITY BEJ ALL 45-10-00
Page 98.147
D633W101-BEJ Sep 05/2002
777 AIRCRAFT MAINTENANCE MANUAL
THIS PAGE IS INTENTIONALLY LEFT BLANK
45-10-00
Page 98.148 D633W101-BEJ Sep 05/2002
CMCS -INPUT MONITORING ANALOG DISCRETE DISPLAY
General
The INPUT MONITORING ANALOG DISCRETE display shows predefined information about the analog discrete inputs to the AIMS cabinets. You can dynamically monitor these discretes.
The display has this information:
*
A title
*
List box
*
Text entry field
*
Buttons.
List Box
The list box has six columns of data. Each column has a heading. Use the scroll bar to show more pages.
These are the column headings:
*
TABLE INDEX
*
CABINET SELECTION
*
SIGNAL NAME
*
BOEING CONNECTOR NAME
*
BOEING CONNECTOR PIN
*
STATE.
TABLE INDEX shows up to four numbers for each analog discrete name.
CABINET SELECTION shows L or R for the AIMS cabinet selection.
SIGNAL NAME shows up to 25 characters for each signal.
BOEING CONNECTOR NAME is eight characters long.
BOEING CONNECTOR PIN is four characters long.