CMCS -ENGINE BALANCING/EXIT APPROVAL DIALOG BOX
EFFECTIVITY BEJ ALL 45-10-00
Page 98.205
D633W101-BEJ Sep 05/2002
CMCS -CENTRAL MAINTENANCE COMPUTER SWITCH CONTROL DIALOG BOX
General
The central maintenance computer switch control dialog box lets the user switch the source of CMCF data to the left or right CMCF.
Display Characteristics
The dialog box has:
*
Title
*
Message field
*
Buttons.
Message Field
The CMCF shows these messages that identifies the CMCF currently in control.
Buttons
Select HELP to show the help dialog box for the shop faults shop faults status dialog box. Help must exist in the CMCF AMI for the HELP selection to show.
Select GO BACK to show all messages except Request Is In Progress. Select GO BACK to remove the shop faults status dialog box and to return to the previous screen.
SWITCH TO LEFT and SWITCH TO RIGHT are toggles. If the left CMCF is in control then the button shows SWITCH TO RIGHT.
If the right CMCF is in control then the button shows SWITCH TO LEFT.
Select SWITCH TO LEFT or SWITCH TO RIGHT to remove the dialog box and to show an inhibit dialog box or a confirmation dialog box.
EFFECTIVITY BEJ ALL 45-10-00
Page 98.206
D633W101-BEJ Sep 05/2002
CMCS -CENTRAL MAINTENANCE COMPUTER SWITCH CONTROL DIALOG BOX
EFFECTIVITY BEJ ALL 45-10-00
Page 98.207
D633W101-BEJ Sep 05/2002
CMCS -CENTRAL MAINTENANCE COMPUTER SWITCH CONTROL INHIBIT DIALOG BOX
General
The central maintenance computer switch control inhibit dialog box shows if a condition exists that affects the ability of the CMCF to switch sources.
Display Characteristics
The dialog box has:
*
Title
*
Message field
*
Buttons.
Message Field
The CMCF shows one or more messages that identify the specific inhibits.
Buttons
Select HELP to show the help dialog box for the central maintenance computer switch control dialog box. Help text for the dialog box must be in the CMCF AMI for HELP to show.
Select GO BACK to remove the dialog box to return to the previous display.
EFFECTIVITY BEJ ALL 45-10-00
Page 98.208
D633W101-BEJ Sep 05/2002
CMCS -CENTRAL MAINTENANCE COMPUTER SWITCH CONTROL INHIBIT DIALOG BOX
EFFECTIVITY BEJ ALL 45-10-00
Page 98.209
D633W101-BEJ Sep 05/2002
CMCS -CENTRAL MAINTENANCE COMPUTER SWITCH CONTROL CONFIRMATION DIALOG BOXES
General Select GO BACK on the dialog box to remove all dialog boxes
and to return to the previous display. If there are no inhibits, the selection of SWITCH TO LEFT or SWITCH TO RIGHT causes a confirmation dialog box to show.
A YES selection on the confirmation dialog box causes another dialog box to show while the CMCF switches sources.
Dialog Box Characteristics
Each dialog box has:
*
Title
*
Message Field
*
Buttons.
Message Field
The message field on each dialog identifies the current condition of the CMCF and provides instructions.
Buttons
The first dialog box has three buttons.
Select YES to show the second dialog box.
Select HELP on both to show the help dialog box for the central maintenance computer switch control dialog box. Help must exist in the CMCF AMI for the HELP selection to show.
EFFECTIVITY BEJ ALL 45-10-00
Page 98.210
D633W101-BEJ Sep 05/2002
CMCS -CENTRAL MAINTENANCE COMPUTER SWITCH CONTROL CONFIRMATION DIALOG BOXES
EFFECTIVITY BEJ ALL 45-10-00
Page 98.211
D633W101-BEJ Sep 05/2002
CMCS -SPECIAL FUNCTIONS DIALOG BOX
General
The SPECIAL FUNCTIONS selection supplies you with access to airplane systems that have unique maintenance functions.
Many ATA systems and LRUs have unique requirements that cause additional dialog boxes to show before the function starts. The types of dialog boxes include:
*
Precondition dialog box
*
Inhibit dialog box
*
Interference dialog box